Ramakrishnan Jeevan B, Danner Christopher J, Yee Suzanne W
Department of Otolaryngology-Head and Neck Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
Otolaryngol Head Neck Surg. 2007 Mar;136(3):357-61. doi: 10.1016/j.otohns.2006.11.010.
To evaluate the long-term outcome of correction of nasal valve collapse with a porous polyethylene implant.
Retrospective review from November 1999 to December 2005. Nasal valve collapse was corrected with a porous polyethylene implant in 12 adults. Main outcome measures included relief of nasal obstruction and complications. Independent variables included other causes of nasal obstruction and need for revision surgery. Simple statistical analysis was performed.
Median follow-up was 5.6 years (58 months). 75% had complete resolution of nasal obstruction. 100% had complete resolution of nasal obstruction at 6 months and had coexisting causes of nasal obstruction. The implant extrusion rate was 21%. 42% went on to have revision surgery.
Correction of nasal valve collapse with a porous polyethylene implant provided good long-term symptomatic relief of nasal obstruction, but with significant incidence of infection, implant extrusion, and need for revision surgery. The use of this implant should be reserved for cases in which autogenous graft material is not available.