Real-time reading in mammography breast screening.

作者信息

Mariotto R, Brancato B, Bonetti F, Manfrin E, Strabbioli M, Mercanti A, Falsirollo F, Bricolo P, Pistolesi G F

机构信息

Centro di Prevenzione Senologica, Ospedale di Marzana, Piazza R. Lambranzi 1, I-37034, Verona, and Istituto di Anatomia Patologica, Università degli Studi di Verona, Italy.

出版信息

Radiol Med. 2007 Mar;112(2):287-303. doi: 10.1007/s11547-007-0142-8. Epub 2007 Mar 19.

Abstract

PURPOSE

This study was undertaken to assess the role of real-time reading in the mammography screening programme carried out at the Hospital of Marzana, Verona, Italy.

MATERIALS AND METHODS

During the 5-year period 1999-2004, 54,472 women attended the screening programme (32,291 first calls: unadjusted uptake 41.4%, adjusted uptake 50.3%; 21,551 2- year routine recalls: unadjusted uptake 86.4%, adjusted uptake 89.9%). Further diagnostic investigations [(FDI), imaging and cytohistological] were performed immediately after real-time reading of the screening mammograms (FDI rate among first calls 10.9%; FDI rate among 2-year recalls 5.4%). Overall, cytohistological FDI were requested in 27% of imaging FDI, with a clear prevalence of cytological [fine-needle aspiration cytology (FNAC) 87%] over histological procedures [core needle biopsy (CNB) 11%; vacuum aspiration biopsy (VAB) 2%].

RESULTS

Imaging FDI proved to be conclusive in 73%. Cytohistological FDI led to the use of surgical biopsy (SB) in 39.5% (ratio between benign and malignant SB: 0.19/first calls, 0.14/2-year recalls). There were a total of 427 screen-detected breast cancers (BC), with a very good breast cancer detection rate (BCDR/first calls 9.7 per thousand; BCDR/2-year recalls 5.1 per thousand). In the 427 screen-detected BC, the incidence of pTis, pT1a,b cancers was 59.6% (diagnostic anticipation); the incidence of pN0 cancers was 61.2%; the incidence of conservative surgical procedures was 78.6%. In interval cancers, the false negative rate was 8.3% only, whereas the proportional incidence was very low indeed (14% first year; 38% second year).

CONCLUSIONS

The high sensitivity exhibited by the Marzana mammography screening programme suggests that the value of real-time reading should be validated by other programmes adopting a similar approach.

摘要

目的

本研究旨在评估实时读片在意大利维罗纳马尔扎纳医院开展的乳腺钼靶筛查项目中的作用。

材料与方法

在1999年至2004年的5年期间,54472名女性参加了筛查项目(首次筛查32291人:未调整的参与率41.4%,调整后的参与率50.3%;两年期常规召回21551人:未调整的参与率86.4%,调整后的参与率89.9%)。在对筛查乳腺钼靶片进行实时读片后,立即进行进一步的诊断性检查[(FDI),影像学和细胞组织学检查](首次筛查中的FDI率为10.9%;两年期召回中的FDI率为5.4%)。总体而言,在27%的影像学FDI中需要进行细胞组织学FDI,细胞学[细针穿刺细胞学检查(FNAC)87%]明显比组织学检查程序[粗针穿刺活检(CNB)11%;真空抽吸活检(VAB)2%]更为普遍。

结果

73%的影像学FDI结果具有决定性意义。细胞组织学FDI导致39.5%的患者采用手术活检(SB)(良性与恶性SB的比例:首次筛查为0.19,两年期召回为0.14)。总共筛查出427例乳腺癌(BC),乳腺癌检出率非常高(首次筛查的BCDR为千分之9.7;两年期召回的BCDR为千分之5.1)。在427例筛查出的BC中,pTis、pT1a、b期癌症的发生率为59.6%(诊断提前);pN0期癌症的发生率为61.2%;保乳手术的发生率为78.6%。在间隔期癌症中,假阴性率仅为8.3%,而比例发生率确实非常低(第一年为14%;第二年为38%)。

结论

马尔扎纳乳腺钼靶筛查项目表现出的高灵敏度表明,实时读片的价值应由采用类似方法的其他项目进行验证。