Suppr超能文献

Tolerability and infusion time of an accelerated infusion dobutamine echocardiography protocol.

作者信息

Pastorius Catherine A, Knickelbine Thomas, Schum Kevin, Nelson Teresa F, Harris Kevin M

机构信息

Minneapolis Heart Institute Foundation at Abbott Northwestern Hospital, Minneapolis, Minnesota 55407, USA.

出版信息

Echocardiography. 2007 Apr;24(4):393-6. doi: 10.1111/j.1540-8175.2007.00401.x.

Abstract

OBJECTIVES

A new, accelerated dobutamine-atropine stress echocardiography (DASE) protocol (baseline 20 mcg/kg/min; 40 mcg/kg/min) was compared with a standard protocol in patients with suspected coronary artery disease (CAD) to evaluate tolerability, length of infusion, and overall test times, as well as safety.

METHODS

Patients received the DASE or the standard protocol on an alternating basis (n = 164).

RESULTS

Total test time, including patient recovery (HR < 100 bpm), dropped from an average of 19:23-12:12 min (p < 0.0001). Average symptom duration decreased from 5:50 to 3:17 min (p < 0.01). Women had shorter total test times in both accelerated and standard protocols compared to that of men.

CONCLUSIONS

The accelerated DASE protocol is a well tolerated alternative to standard dobutamine stress testing allowing practitioners to reduce test times without increasing the incidence of arrhythmias. Patients in the accelerated arm also had shorter duration of symptoms.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验