An in vitro comparison of the force decay generated by different commercially available elastomeric chains and NiTi closed coil springs.

作者信息

Santos Ana Cristina Soares, Tortamano André, Naccarato Sandra Regina Frazatto, Dominguez-Rodriguez Gladys Cristina, Vigorito Julio Wilson

机构信息

Department of Orthodontics, School of Dentistry, University of São Paulo, Rua Oscar Freire 2121-1101, Pinheiros, São Paulo, SP, Brazil, CEP 05409-011.

出版信息

Braz Oral Res. 2007 Jan-Mar;21(1):51-7. doi: 10.1590/s1806-83242007000100009.

Abstract

This in vitro study was designed to compare the forces generated by commercially available elastomeric chains and NiTi closed coil springs, and to determine their force decay pattern. Forty elastomeric chains and forty NiTi closed coil springs were divided into 4 groups according to the following manufacturers: (1) Morelli, (2) Abzil, (3) TP Orthodontics and (4) American Orthodontics. The specimens were extended to twice their original length and stored in artificial saliva at 37 degrees C. Initial force was measured by means of an Instron universal testing machine and then at 1, 4, 7, 14, 21, and 28 days. The results revealed that the elastomeric chains delivered a mean initial force of 347 g for Morelli, 351 g for American Orthodontics, 402 g for Abzil, and 404 g for TP Orthodontics. The NiTi closed coil springs generated a mean initial force of 196 g for American Orthodontics, 208 g for TP Orthodontics, 216 g for Abzil, and 223 g for Morelli. The mean percentage of force decay observed after 28 days for the elastomeric chains was 37.4% for TP Orthodontics(R), 48.1% for American Orthodontics, 65.4% for Morelli, and 71.6% for Abzil. After 28 days, the NiTi closed coil springs presented a mean percentage of force decay of 22.6% for American Orthodontics, 29.8% for Abzil, 30.6% for Morelli, and 45.8% for TP Orthodontics. At the end of the study, significant differences were observed between the elastomeric chains and the NiTi closed coil springs. The results indicated that the studied NiTi closed coil springs are more adequate for dental movement than the elastomeric chains.

摘要

本体外研究旨在比较市售弹性链和镍钛闭合螺旋弹簧产生的力,并确定其力衰减模式。根据以下制造商将40根弹性链和40根镍钛闭合螺旋弹簧分为4组:(1)莫雷利,(2)阿齐尔,(3)TP正畸公司,(4)美国正畸公司。将标本拉伸至其原始长度的两倍,并保存在37摄氏度的人工唾液中。通过英斯特朗万能试验机测量初始力,然后在第1、4、7、14、21和28天测量。结果显示,莫雷利弹性链的平均初始力为347克,美国正畸公司为351克,阿齐尔为402克,TP正畸公司为404克。镍钛闭合螺旋弹簧的平均初始力为:美国正畸公司196克,TP正畸公司208克,阿齐尔216克,莫雷利223克。28天后,TP正畸公司(R)弹性链的平均力衰减百分比为37.4%,美国正畸公司为48.1%,莫雷利为65.4%,阿齐尔为71.6%。28天后,镍钛闭合螺旋弹簧的平均力衰减百分比为:美国正畸公司22.6%,阿齐尔29.8%,莫雷利30.6%,TP正畸公司45.8%。在研究结束时,观察到弹性链和镍钛闭合螺旋弹簧之间存在显著差异。结果表明,所研究的镍钛闭合螺旋弹簧比弹性链更适合牙齿移动。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验