A sensor configuration for oxygen determination based on luminescence quenching is presented in which the measured parameter is closely related to the luminescence lifetime. The sensing film is based on the dye platinum octaethylporphyrin complex immobilised in a polystyrene membrane and stabilised with the heterocyclic amine DABCO. In this report, we study the feasibility of using photodiodes as elements to be coated by this oxygen sensing film with the aim of obtaining a sensing device whose small size makes it possible to embed it into a portable measurement system. In addition to the concomitant sensor miniaturisation, several advantages have been demonstrated such as fast response, low energy consumption, the lack of any need for optical filter elements and less tendency to photobleaching than with previous configurations. A complete study of the coated photodetector preparation was carried out in order to optimise the specifications of the portable instrument where the photodetector is included, such as: repeatability, transient response and selectivity. We propose a preparation procedure for coating photodetectors with this film that has demonstrated the capacity to produce repetitive and reliable sensing devices.
本文介绍了一种基于发光猝灭的氧测定传感器配置,其中测量参数与发光寿命密切相关。传感膜基于固定在聚苯乙烯膜中并用杂环胺DABCO稳定的染料铂八乙基卟啉配合物。在本报告中,我们研究了使用光电二极管作为被该氧传感膜覆盖的元件的可行性,目的是获得一种尺寸小到可以嵌入便携式测量系统的传感装置。除了随之而来的传感器小型化之外,还证明了该装置具有几个优点,如响应速度快、能耗低、无需任何光学滤波元件,并且与先前的配置相比光漂白倾向较小。为了优化包含该光电探测器的便携式仪器的规格,如重复性、瞬态响应和选择性,对涂覆光电探测器的制备进行了全面研究。我们提出了一种用该膜涂覆光电探测器的制备程序,该程序已证明能够生产出重复性好且可靠的传感装置。