Agarwal A, Manglona A, Loughlin K R
Division of Urology and Reproductive-Endocrinology Laboratory, Brigham and Women's Hospital, Boston, Massachusetts 02115.
Fertil Steril. 1991 Dec;56(6):1162-5. doi: 10.1016/s0015-0282(16)54733-5.
To explore the possibility of using the L4 membrane filtration device for processing of spermatozoa for intrauterine insemination and other assisted reproductive techniques.
DESIGN, SETTING, PATIENTS: Semen samples from 15 patients attending an infertility clinic of a tertiary referral institution and from seven fertile donors were used for the study.
The effect of L4 membrane filtration was studied on the following semen parameters: sperm motility, velocity, percentage of normal and abnormal sperm forms, and percentage and concentration of round cells in semen.
The statistical analysis of data from both the subfertile patient population and the normal fertile donor group showed similar improvement in semen quality after L4 membrane filtration. Therefore, the results for these two groups were combined for statistical purposes. Our findings demonstrate a significant increase in normal sperm forms and a decrease in abnormal forms after filtration of specimens through the L4 membrane. In all subjects, the mean sperm motility increased from 47% to 77% (P less than 0.0001); velocity increased from 30 to 48 microns/seconds (P less than 0.0001); normal sperm forms increased from 53% to 84% (P less than 0.0001); abnormal forms decreased from 28% to 10% (head defects) (P less than 0.0001); neck defects from 3.5% to 1% (P less than 0.0006); tail defects from 8% to 3.5% (P less than 0.005); and undifferentiated round cells decreased from 6% to less than 1% (P less than 0.002) after filtration. The concentration of round cells counted by the Makler chamber (Sefi Medical, Haifa, Israel) decreased significantly from 6 x 10(6)/mL to 0.2 x 10(6)/mL (P less than 0.0003). Similarly, white blood cell counts measured by the Endtz test also decreased from 3.4 x 10(6)/mL to less than 0.1 x 10(6) (P less than 0.043).
We conclude that the filtration of the semen specimens through L4 membrane results in a significant improvement in semen parameters and should be considered as an adjunct in sperm processing.
探讨使用L4膜过滤装置处理用于宫内人工授精及其他辅助生殖技术的精子的可能性。
设计、地点、患者:来自一家三级转诊机构不育门诊的15名患者以及7名生育能力正常的供者的精液样本用于本研究。
研究L4膜过滤对以下精液参数的影响:精子活力、速度、正常和异常精子形态百分比、精液中圆形细胞百分比及浓度。
对不育患者群体和正常生育供者组的数据进行统计分析,结果显示L4膜过滤后两组精液质量均有相似改善。因此,为统计目的将两组结果合并。我们的研究结果表明,通过L4膜过滤标本后,正常精子形态显著增加,异常形态减少。在所有受试者中,过滤后精子平均活力从47%增至77%(P<0.0001);速度从30微米/秒增至48微米/秒(P<0.0001);正常精子形态从53%增至84%(P<0.0001);异常形态从28%降至10%(头部缺陷)(P<0.0001);颈部缺陷从3.5%降至1%(P<0.0006);尾部缺陷从8%降至3.5%(P<0.005);未分化圆形细胞从6%降至不足1%(P<0.002)。用Makler计数板(以色列海法Sefi Medical公司)计数的圆形细胞浓度从6×10⁶/mL显著降至0.2×10⁶/mL(P<0.0003)。同样,用Endtz试验测得的白细胞计数也从3.4×10⁶/mL降至不足0.1×10⁶/mL(P<0.043)。
我们得出结论,通过L4膜过滤精液标本可显著改善精液参数,应将其视为精子处理的辅助手段。