Abstract

OBJECTIVE

To compare as-received copper-nickel-titanium (CuNiTi) archwires to those used in patients by means of differential scanning calorimetry (DSC). Also, the thermal or phase properties of 27 degrees C, 35 degrees C, and 40 degrees C CuNiTi archwires were studied to ascertain if their properties match those indicated by the manufacturer.

MATERIALS AND METHODS

Six wires of 27 degrees C, 35 degrees C, and 40 degrees C CuNiTi were tested as-received, and six each of the 27 degrees C and 35 degrees C wires were examined after use in patients for an average of approximately 9 and 7 weeks, respectively. Segments of archwire were investigated by DSC over the temperature range from -100 degrees C to 150 degrees C at 10 degrees C per minute.

RESULTS

There were no significant differences between as-received and clinically used 27 degrees C and 35 degrees C wires for all parameters (heating onset, endset, and enthalpy and cooling onset, endset, and enthalpy), except the 27 degrees C wires exhibited a significant decrease in the heating enthalpy associated with the martensite-to-austenite transition after clinical use. The heating endsets (austenite finish temperatures) of the 27 degrees C and 35 degrees C wires were within 2 degrees C of those claimed by the manufacturer, but the 40 degrees C wires were found to be nearer to 36 degrees C than 40 degrees C.

CONCLUSIONS

Clinical use of CuNiTi wires resulted in few differences when compared with as-received wires analyzed by DSC. Two temperature varieties of CuNiTi are reasonably within the parameters of those identified by the manufacturer.

摘要

目的

通过差示扫描量热法(DSC)比较收到的铜镍钛(CuNiTi)弓丝与患者使用过的弓丝。此外,研究了27℃、35℃和40℃的CuNiTi弓丝的热性能或相性能,以确定其性能是否与制造商标明的性能相符。

材料与方法

对收到的6根27℃、35℃和40℃的CuNiTi弓丝进行测试,对27℃和35℃的弓丝各6根在患者使用平均约9周和7周后进行检查。通过DSC在-100℃至150℃的温度范围内以每分钟10℃的速率对弓丝片段进行研究。

结果

对于所有参数(加热起始温度、终止温度和焓以及冷却起始温度、终止温度和焓),收到的27℃和35℃弓丝与临床使用后的弓丝之间没有显著差异,除了27℃的弓丝在临床使用后与马氏体向奥氏体转变相关的加热焓有显著降低。27℃和35℃弓丝的加热终止温度(奥氏体终了温度)在制造商声称的温度范围内2℃以内,但发现40℃的弓丝更接近36℃而不是40℃。

结论

与通过DSC分析的收到的弓丝相比,CuNiTi弓丝的临床使用导致的差异很小。两种温度规格的CuNiTi弓丝在制造商确定的参数范围内基本合理。