Hyde Damon, Miller Eric, Brooks Dana H, Ntziachristos Vasilis
Electrical and Computer Engineering Department, Northeastern University, Boston, MA 02115, USA.
IEEE Trans Med Imaging. 2007 Jul;26(7):893-905. doi: 10.1109/TMI.2007.895467.
We examine the problem of fluorescence molecular tomography using the normalized Born approximation, termed herein the Born ratio, from a statistical perspective. Experimentally verified noise models for received signals at the excitation and emission wavelengths are combined to generate a stochastic model for the Born ratio. This model is then utilized within a maximum likelihood framework to obtain an inverse solution based on a fixed point iteration. Results are presented for three experimental scenarios: phantom data with a homogeneous background, phantoms implanted within a small animal, and in vivo data using an exogenous probe.
我们从统计学角度研究了使用归一化玻恩近似(本文称为玻恩比率)的荧光分子断层扫描问题。将激发和发射波长处接收信号的经过实验验证的噪声模型相结合,以生成玻恩比率的随机模型。然后在最大似然框架内利用该模型,通过定点迭代获得反解。给出了三种实验场景的结果:具有均匀背景的体模数据、植入小动物体内的体模以及使用外源性探针的体内数据。