Suppr超能文献

时间减影图像在识别连续全身骨扫描的间期变化中的应用:放射科医生表现的JAFROC分析

Usefulness of temporal subtraction images for identification of interval changes in successive whole-body bone scans: JAFROC analysis of radiologists' performance.

作者信息

Shiraishi Junji, Appelbaum Daniel, Pu Yonglin, Li Qiang, Pesce Lorenzo, Doi Kunio

机构信息

Department of Radiology, Kurt Rossmann Laboratories for Radiologic Image Research, MC2026, The University of Chicago, Chicago, IL 60637, USA.

出版信息

Acad Radiol. 2007 Aug;14(8):959-66. doi: 10.1016/j.acra.2007.04.005.

Abstract

RATIONALE AND OBJECTIVES

We evaluated the usefulness of temporal subtraction images obtained from two successive whole-body bone scans, in terms of improvement in radiologists' diagnostic accuracy in detecting interval changes and of a reduction in reading time, by use of a jackknife free-response receiver operating characteristic (JAFROC) analysis method.

MATERIALS AND METHODS

Twenty pairs of successive whole-body bone scans (72 consented interval changes) and their temporal subtraction images were used for an observer performance study. Our institutional review board approved the use of this database and the participation of radiologists in this study. In the first session of the observer study, without temporal subtraction images, the previous and current images were shown to five radiologists independently for their marking of the locations on current images and confidence ratings on potential interval changes from previous images. In the second session, temporal subtraction images were shown together with the modified previous and current images. JAFROC analysis was used for assessing the statistical significance of differences between radiologists' performance without and with temporal subtraction images.

RESULTS

The average sensitivity for detecting interval changes was improved from 58.6% to 73.2% at a false-positive rate of two per case by use of temporal subtraction images, and the difference was statistically significant by use of JAFROC analysis (P = .035). In addition, the mean reading time per case was reduced considerably from 134 seconds to 91 seconds (P < .01).

CONCLUSIONS

Temporal subtraction imaging for successive whole-body bone scans has the potential greatly to assist radiologists by increasing both their accuracy and productivity.

摘要

原理与目的

我们通过使用留一法自由响应接收器操作特性(JAFROC)分析方法,评估了从连续两次全身骨扫描获得的时间减影图像在提高放射科医生检测间期变化的诊断准确性以及减少阅片时间方面的有用性。

材料与方法

20对连续的全身骨扫描(72例同意的间期变化)及其时间减影图像用于观察者性能研究。我们机构的审查委员会批准了该数据库的使用以及放射科医生参与本研究。在观察者研究的第一阶段,在没有时间减影图像的情况下,将先前和当前的图像分别展示给五位放射科医生,让他们在当前图像上标记位置,并对与先前图像相比潜在的间期变化给出置信度评级。在第二阶段,将时间减影图像与修改后的先前和当前图像一起展示。JAFROC分析用于评估放射科医生在有无时间减影图像时性能差异的统计学意义。

结果

通过使用时间减影图像,在每例假阳性率为2的情况下,检测间期变化的平均敏感度从58.6%提高到了73.2%,并且通过JAFROC分析,差异具有统计学意义(P = 0.035)。此外,每例的平均阅片时间从134秒大幅减少至91秒(P < 0.01)。

结论

连续全身骨扫描的时间减影成像有潜力通过提高准确性和效率极大地帮助放射科医生。