Liu Rui, Liang Pei
Key Laboratory of Pesticide & Chemical Biology of Ministry of Education, College of Chemistry, Central China Normal University, Wuhan 430079, PR China.
J Hazard Mater. 2008 Mar 21;152(1):166-71. doi: 10.1016/j.jhazmat.2007.06.081. Epub 2007 Jun 29.
Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer TiO2) was prepared by sol-gel method and characterized using X-ray diffraction (XRD) and scanning electron microscope (SEM). The adsorptive capability of immobilized nanometer TiO2 for lead was assessed in this work using column method. It was found that lead can be quantitatively retained by immobilized nanometer TiO2 in the pH range 4-7, then eluted completely with 1.0molL(-1) HCl. The adsorption capacity of immobilized nanometer TiO2 for Pb was found to be 3.16mgg(-1). A new method has been developed for the determination of trace lead based on preconcentration with a microcolumn packed with immobilized nanometer TiO2 prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS). The detection limit of this method for Pb was 9.5ngL(-1) with an enrichment factor of 50, and the relative standard deviations (R.S.D.s) was 3.2% at the 10ngmL(-1) Pb level. The method was validated using a certified reference material, and was applied for the determination of trace lead in water samples.
采用溶胶-凝胶法制备了负载在硅胶上的纳米二氧化钛(负载型纳米TiO₂),并通过X射线衍射(XRD)和扫描电子显微镜(SEM)对其进行了表征。本工作采用柱法评估了负载型纳米TiO₂对铅的吸附能力。结果发现,负载型纳米TiO₂在pH值为4-7的范围内能定量保留铅,然后用1.0molL⁻¹ HCl将其完全洗脱。负载型纳米TiO₂对Pb的吸附容量为3.16mgg⁻¹。建立了一种新的痕量铅测定方法,即在石墨炉原子吸收光谱法(GFAAS)测定之前,用填充有负载型纳米TiO₂的微柱进行预富集。该方法对Pb的检出限为9.5ngL⁻¹,富集倍数为50,在10ngmL⁻¹ Pb水平下的相对标准偏差(R.S.D.s)为3.2%。该方法通过使用有证标准物质进行了验证,并应用于水样中痕量铅的测定。