Suppr超能文献

锝-99m 苏单抗用于全关节置换术后假体感染的诊断

Use of (99m)Tc-sulesomab for the diagnosis of prosthesis infection after total joint arthroplasty.

作者信息

Pakos E E, Fotopoulos A D, Stafilas K S, Gavriilidis I, Al Boukarali G, Tsiouris S, Xenakis T A

机构信息

Department of Orthopaedic Surgery, University Hospital of Ioannina, University of Ioannina School of Medicine, Ioannina, Greece.

出版信息

J Int Med Res. 2007 Jul-Aug;35(4):474-81. doi: 10.1177/147323000703500406.

Abstract

This study aimed to evaluate the diagnostic efficacy of antigranulocyte scintigraphy using the antibody fragment (99m)Tc-sulesomab (LeukoScan) for the diagnosis of prosthesis infection in patients with total hip or knee arthroplasty. The results from 19 patients with suspected total joint arthroplasty infection who had undergone a three-phase bone scan and a subsequent examination with (99m)Tc-sulesomab during a 1-year period were reviewed. Twelve patients were shown to have prosthesis infection on culture of aspirated synovial fluid or intra-operative samples. The overall sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy for (99m)Tc-sulesomab were 75%, 86%, 90%, 66% and 79%, respectively, compared with 54%, 83%, 88%, 45% and 63%, respectively, for the three-phase bone scan. This study showed that (99m)Tc-sulesomab had good diagnostic value for the detection of prosthesis infection. The combination of (99m)Tc-sulesomab with other laboratory or imaging examinations may improve diagnostic performance in prosthesis infection and should be investigated further.

摘要

本研究旨在评估使用抗体片段(99m)锝-舒来昔单抗(白细胞扫描)的抗粒细胞闪烁扫描术对全髋关节或膝关节置换术患者假体感染的诊断效能。回顾了19例疑似全关节置换术感染患者的结果,这些患者在1年期间接受了三相骨扫描以及随后的(99m)锝-舒来昔单抗检查。12例患者经抽吸的滑液或术中样本培养显示有假体感染。(99m)锝-舒来昔单抗的总体敏感性、特异性、阳性和阴性预测值以及诊断准确性分别为75%、86%、90%、66%和79%,而三相骨扫描的相应数值分别为54%、83%、88%、45%和63%。本研究表明,(99m)锝-舒来昔单抗对假体感染的检测具有良好的诊断价值。(99m)锝-舒来昔单抗与其他实验室或影像学检查相结合可能会提高假体感染的诊断性能,应进一步研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验