Suppr超能文献

利用L-[β-11C]多巴正电子发射断层扫描技术对人体中枢多巴胺合成进行映射。

Mapping of central dopamine synthesis in man, using positron emission tomography with L-[beta-11C]DOPA.

作者信息

Ito Hiroshi, Shidahara Miho, Takano Harumasa, Takahashi Hidehiko, Nozaki Shoko, Suhara Tetsuya

机构信息

Clinical Neuroimaging Team, Molecular Neuroimaging Group, Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Chiba 263-8555, Japan.

出版信息

Ann Nucl Med. 2007 Aug;21(6):355-60. doi: 10.1007/s12149-007-0033-z. Epub 2007 Aug 27.

Abstract

OBJECTIVE

To estimate the presynaptic function of the central dopaminergic system, positron emission tomography measurement of the endogenous dopamine synthesis rate was performed with L-[beta-11C]DOPA. In the present study, we developed a simple method for calculating an indicator of the dopamine synthesis rate with L-[beta-11C]DOPA on a voxel-by-voxel basis for parametric mapping.

METHODS

After intravenous injection of L-[beta-11C]DOPA, dynamic scanning was performed on ten healthy men for 89 min. The dopamine synthesis ratio was calculated on a voxel-by-voxel basis as the ratio of the area under the time-activity curves of brain regions to the reference brain region, that is, occipital cortex. The overall uptake rate constant as an indicator of dopamine synthesis was also calculated by kinetic and graphical analyses.

RESULTS

The dopamine synthesis ratio calculated by the present method was in good agreement with the indicators of dopamine synthesis calculated by kinetic and graphical analyses, although a systemic underestimation was observed, especially when the integration interval was set in the early phase of the scan duration. In particular, underestimations were prominent in brain regions with relatively lower influx rate constant K1.

CONCLUSIONS

By this method, regional dopamine synthesis could be estimated on a voxel-by-voxel basis. This method does not need an arterial input function and should prove to be useful for clinical research.

摘要

目的

为评估中枢多巴胺能系统的突触前功能,采用L-[β-11C]多巴进行正电子发射断层扫描测量内源性多巴胺合成率。在本研究中,我们开发了一种简单的方法,用于在体素基础上计算L-[β-11C]多巴的多巴胺合成率指标,以进行参数映射。

方法

对10名健康男性静脉注射L-[β-11C]多巴后,进行89分钟的动态扫描。多巴胺合成率在体素基础上计算为脑区时间-活性曲线下面积与参考脑区(即枕叶皮质)面积的比值。还通过动力学和图像分析计算了作为多巴胺合成指标的总体摄取速率常数。

结果

尽管观察到系统性低估,尤其是在扫描持续时间早期设定积分区间时,但本方法计算的多巴胺合成率与动力学和图像分析计算的多巴胺合成指标高度一致。特别是,在流入速率常数K1相对较低的脑区,低估现象尤为突出。

结论

通过这种方法,可以在体素基础上估计区域多巴胺合成。该方法不需要动脉输入函数,应证明对临床研究有用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验