Miyawaki Takashi, Kawashima Ayato, Honda Katsuhisa
Department of Environmental Science for Industry, Ehime University, 3-5-7 Tarumi, Matsuyama 790-8566, Japan.
Chemosphere. 2008 Jan;70(4):648-55. doi: 10.1016/j.chemosphere.2007.06.068. Epub 2007 Aug 27.
A method involving supercritical fluid extraction (SFE) with a solid phase trap containing activated alumina was investigated for the rapid analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin like polychlorinated biphenyls (DL-PCBs) in soils and sediments. The samples were extracted by using supercritical carbon dioxide with water (2% versus CO(2) flow velocity) being used as an entrainer at a pressure of 30 MPa and a temperature of 130 degrees C for 50 min. The extracts were adsorbed on an activated alumina trap that was maintained at a temperature of 150 degrees C, and then, PCDD/DFs and DL-PCBs were eluted with 20 ml of hexane at 60 degrees C. After concentration, they were measured with a high-resolution gas chromatograph interfaced to a high-resolution mass spectrometric detector. The average concentrations of PCDD/DFs and DL-PCBs corresponded to the results obtained by the conventional method, and the reproducibility of this SFE method was below 21% of the relative standard deviations for all samples. The total time required for the analysis of the pretreatment of this method was only 2 h.
研究了一种采用含活性氧化铝的固相捕集器进行超临界流体萃取(SFE)的方法,用于快速分析土壤和沉积物中的多氯代二苯并 - 对 - 二噁英(PCDDs)、多氯代二苯并呋喃(PCDFs)和二噁英类多氯联苯(DL - PCBs)。样品通过使用超临界二氧化碳进行萃取,水(相对于二氧化碳流速为2%)作为夹带剂,在30 MPa的压力和130℃的温度下萃取50分钟。萃取物吸附在保持在150℃的活性氧化铝捕集器上,然后,在60℃下用20 ml己烷洗脱PCDD/DFs和DL - PCBs。浓缩后,用与高分辨率质谱检测器联用的高分辨率气相色谱仪进行测定。PCDD/DFs和DL - PCBs的平均浓度与传统方法获得的结果一致,该SFE方法的重现性对于所有样品而言相对标准偏差低于21%。该方法预处理分析所需的总时间仅为2小时。