We find that the current-sensitive noise thermometer is a satisfactory sensor of absolute temperature down to 2 mK and possibly below. Its field of application is primarily to magnetically and electrically quiet situations where accuracy is important and high precision is not required. For example the noise thermometer is an ideal instrument for calibrating a secondary thermometer, such as a pressure thermometer, whose calibration can readily and accurately be transferred from one laboratory to another. Further instrumental development for millidegree applications seems unnecessary at present. Rather the major problems in millikelvin noise thermometry that require attention in the immediate future involve establishing thermal contact to the thermometer and reducing its thermal response time.

摘要

我们发现,电流敏感噪声温度计是一种令人满意的绝对温度传感器,可低至 2 mK,甚至更低。它的应用领域主要是在磁场和电场安静的情况下,这些情况下准确性很重要,而不需要高精度。例如,噪声温度计是校准二次温度计(如压力温度计)的理想仪器,其校准可以很容易且准确地从一个实验室转移到另一个实验室。目前,进一步开发用于毫开尔文应用的仪器似乎没有必要。相反,在不久的将来,毫开尔文噪声温度计需要关注的主要问题涉及到与温度计建立热接触和减少其热响应时间。

相似文献

2
Primary current-sensing noise thermometry in the millikelvin regime.
Philos Trans A Math Phys Eng Sci. 2016 Mar 28;374(2064):20150054. doi: 10.1098/rsta.2015.0054.
3
Primary electronic thermometry using the shot noise of a tunnel junction.
Science. 2003 Jun 20;300(5627):1929-32. doi: 10.1126/science.1084647.
4
Noise thermometry at ultra-low temperatures.
Philos Trans A Math Phys Eng Sci. 2016 Mar 28;374(2064):20150051. doi: 10.1098/rsta.2015.0051.
5
Nanoelectronic primary thermometry below 4 mK.
Nat Commun. 2016 Jan 27;7:10455. doi: 10.1038/ncomms10455.
6
7
High-resolution ultrasonic thermometer for radiation dosimetry.
J Acoust Soc Am. 2008 Dec;124(6):3481-90. doi: 10.1121/1.2997431.
8
Calibration of an ingestible temperature sensor.
Physiol Meas. 2008 Nov;29(11):N71-8. doi: 10.1088/0967-3334/29/11/N01. Epub 2008 Oct 9.
9
A SQUID-based primary noise thermometer for low-temperature metrology.
Philos Trans A Math Phys Eng Sci. 2016 Mar 28;374(2064):20150050. doi: 10.1098/rsta.2015.0050.
10
Diamond with Sp-Sp composite phase for thermometry at Millikelvin temperatures.
Nat Commun. 2024 May 8;15(1):3871. doi: 10.1038/s41467-024-48137-z.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验