Suppr超能文献

采用胶束稳定室温磷光法测定阿替洛尔。

Determination of atenolol by the micelle-stabilized room-temperature phosphorescence methodology.

作者信息

Castillo Marcela A, Gambino Luisina Ongaro, Polizzi Germán, Andreetta Héctor A, Bruzzone Liliana

机构信息

División Química Analítica, Departamento de Química, Facultad de Ciencias Exactas, Universidad Nacional de La Plata, Calle 47 esq. 115, 1900 La Plata, Argentina.

出版信息

Luminescence. 2007 Nov-Dec;22(6):527-33. doi: 10.1002/bio.994.

Abstract

A micellar-stabilized room-temperature phosphorescence (MS-RTP) method for the determination of atenolol has been developed in micellar solutions of sodium dodecylsulphate (SDS) in the presence of thallium(I) as a heavy atom and sodium sulphite as an oxygen scavenger. The effects of thallium(I) nitrate, SDS and sodium sulphite concentrations on atenolol MS-RTP intensity were studied. Optimized conditions to obtain maximum sensitivity were 0.015 mol/L thallium(I) nitrate, 0.1 mol/L SDS and 0.0075 mol/L sodium sulphite. The maximum phosphorescence signal was completely developed in 10 min and the intensity was measured at lambda(ex) = 272 nm and lambda(em) = 412 nm. The linear range of application obtained was 2.01-16.00 microg/mL. The detection limit estimated from the least-squares regression analysis was 0.86 microg/mL and the relative standard deviation of 10 replicates was 1.7%. The proposed method was applied to the determination of atenolol in a pharmaceutical formulation. The quantitation was carried out by means of standard calibration, standard-additions calibration and Youden calibration. These three experiments were necessary to evaluate the presence of constant and proportional errors due to the matrix.

摘要

已开发出一种胶束稳定室温磷光(MS-RTP)法,用于在十二烷基硫酸钠(SDS)胶束溶液中,以铊(I)作为重原子、亚硫酸钠作为除氧剂的条件下测定阿替洛尔。研究了硝酸铊(I)、SDS和亚硫酸钠浓度对阿替洛尔MS-RTP强度的影响。获得最大灵敏度的优化条件为0.015 mol/L硝酸铊(I)、0.1 mol/L SDS和0.0075 mol/L亚硫酸钠。最大磷光信号在10分钟内完全形成,并在激发波长(λex)=272 nm和发射波长(λem)=412 nm处测量强度。得到的线性应用范围为2.01 - 16.00 μg/mL。通过最小二乘回归分析估计的检测限为0.86 μg/mL,10次重复测定的相对标准偏差为1.7%。所提出的方法应用于药物制剂中阿替洛尔的测定。通过标准校准、标准加入校准和尤登校准进行定量。这三个实验对于评估由于基质导致的恒定误差和比例误差的存在是必要的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验