Suppr超能文献

Effect of low fluence diode laser irradiation on the hydraulic conductivity of perfused trabecular meshwork endothelial cell monolayers.

作者信息

Roberts Cynthia J, Rivera Brian K, Grzybowski Deborah M, Mahmoud Ashraf M, Weber Paul A

机构信息

Department of Ophthalmology, The Ohio State University, Columbus 43210, USA.

出版信息

Curr Eye Res. 2007 Jul-Aug;32(7-8):625-38. doi: 10.1080/02713680701486394.

Abstract

OBJECTIVE

To determine the effect of low-fluence diode laser irradiation upon the fluid perfusion characteristics of cultured human trabecular meshwork cell monolayers when placed in a specially designed testing apparatus and subjected to fluid flow driven by a hydrostatic pressure gradient.

METHODS

Two experimental series were conducted. In the first series, six low-fluence diode laser irradiation experiments were conducted using cultured human trabecular meshwork cell monolayers grown on filter supports. Upon reaching a steady state perfusion condition at approximately 5.0 mmHg, monolayers were irradiated at fluencies ranging from 0.2619 to 0.8571 J/cm2 using a diode laser (lambda=810 nm). Perfusion and data collection continued for 45 minutes post-irradiation, after which the monolayers were tested to determine post-experimental viability. Hydraulic conductivity values were analyzed for post-irradiation response in 2.5-minute intervals, grouped by viability. In the second series, a total of six irradiated experiments and six simultaneous nonirradiated control experiments were conducted. Fluence values of 0.3571 J/cm2 (n=3) and 0.4286 J/cm2 (n=3) were used. Hydraulic conductivity values were analyzed for post-irradiation response in 2.5-minute intervals, grouped by irradiated vs. nonirradiated control groups.

RESULTS

In the first series, analysis showed that the viable monolayers exhibited a statistically significant increase in hydraulic conductivity (p<0.001) from 10 minutes post-irradiation onward. The non-viable monolayers exhibited a statistically significant decrease in hydraulic conductivity. In the second series, irradiated groups showed a significant difference (p<0.001) from nonirradiated controls from 10 minutes post-irradiation onward.

CONCLUSION

Low-fluence diode laser irradiation increases hydraulic conductivity in viable perfused TM cell monolayers when compared to baseline values or simultaneous nonirradiated controls while decreasing hydraulic conductivity in nonviable monolayers.