Kobayashi Masayoshi, Imanishi Yoshinori, Ishikawa Masako, Nishida Kohei, Oishi Maaya, Nakamura Satoshi, Sakaida Hiroshi, Maeda Taro, Tsunoda Takatsugu, Matsuura Toru, Majima Yuichi
Department of Otorhinolaryngology-Head and Neck Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie 514-8507, Japan.
Auris Nasus Larynx. 2008 Mar;35(1):53-60. doi: 10.1016/j.anl.2007.04.014. Epub 2007 Sep 14.
The goal of this study was to determine if visual information and test paradigms affect clinical olfactory test results.
Three hundred and ninety-seven Japanese patients with complaints of olfactory dysfunction were administered both a new clinical olfactory test, the Odor Stick Identification Test for Japanese (OSIT-J), and the Japanese benchmark olfactory test, T&T olfactometry. Four different methods were used to administer the OSIT-J combining paradigms using word or picture-word alternatives with the four-plus alternative method based on a top-down strategy or the two-step identification method based on a bottom-up strategy. OSIT-J scores were compared for the different methods, referring to benchmark scores obtained with T&T olfactometry.
OSIT-J scores using picture-word alternatives and the four-plus alternative method showed a stronger correlation with T&T olfactometry test scores than those using word alternatives and the two-step identification method, respectively. The average OSIT-J scores of the four-plus alternative method using picture-word alternatives were significantly higher than those using word alternatives in anosmic and severely hyposmic patients. The time required to administer the OSIT-J using both picture-word alternatives and the four-plus alternative method was the shortest of the four OSIT-J methods.
Visual information and test paradigms may affect clinical olfactory test results. The OSIT-J method using picture-word alternatives and the four-plus alternative method may be the most suitable for clinical practice.
本研究的目的是确定视觉信息和测试范式是否会影响临床嗅觉测试结果。
对397名主诉嗅觉功能障碍的日本患者进行了一项新的临床嗅觉测试——日本嗅觉棒识别测试(OSIT-J),以及日本基准嗅觉测试——T&T嗅觉测量法。使用了四种不同的方法来实施OSIT-J,将使用单词或图文并茂选项的范式与基于自上而下策略的四选加一法或基于自下而上策略的两步识别法相结合。参照T&T嗅觉测量法获得的基准分数,比较不同方法的OSIT-J分数。
与分别使用单词选项和两步识别法相比,使用图文并茂选项和四选加一法的OSIT-J分数与T&T嗅觉测量法测试分数的相关性更强。在嗅觉丧失和严重嗅觉减退的患者中,使用图文并茂选项的四选加一法的OSIT-J平均分数显著高于使用单词选项的分数。使用图文并茂选项和四选加一法实施OSIT-J所需的时间是四种OSIT-J方法中最短的。
视觉信息和测试范式可能会影响临床嗅觉测试结果。使用图文并茂选项和四选加一法的OSIT-J方法可能最适合临床实践。