Suppr超能文献

使用压电激发的毫米级悬臂梁传感器在2.5 fg/mL的浓度下检测和确证苹果汁和牛奶中的葡萄球菌肠毒素B。

Detection and confirmation of staphylococcal enterotoxin B in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL.

作者信息

Maraldo David, Mutharasan Raj

机构信息

Department of Chemical and Biological Engineering, Drexel University, Philadelphia, Pennsylvania 19104, USA.

出版信息

Anal Chem. 2007 Oct 15;79(20):7636-43. doi: 10.1021/ac070589l. Epub 2007 Sep 18.

Abstract

A sensitive and reliable method for the detection of a model toxin, staphylococcal enterotoxin B (SEB) in buffer, apple juice, and milk is shown using piezoelectric-excited, millimeter-sized cantilever (PEMC) sensors. Limit of detection in spiked milk and apple juice samples is 10 and 100 fg, respectively. PEMC sensors (2 mm(2)) are prepared by immobilizing a polyclonal antibody specific to SEB, which was exposed to 1 mL of 1% milk and apple juice containing 10 fg-10 ng. Sensor response to 100 fg, 1 pg, and 10 pg of SEB in apple juice resulted in resonance frequency decreases of 113 +/- 18 (n = 4), 308 +/- 24 (n = 4), and 521 +/- 20 (n = 2) Hz, respectively. In milk, 10 fg, 100 fg, 1 pg, and 10 pg of SEB resulted in resonance frequency decreases of 126 +/- 18 (n = 2), 143 +/- 35 (n = 4), 310 +/- 32 (n = 5), and 557 +/- 25 (n = 2) Hz, respectively. Positive detection of SEB in the sample solution was observed within the first 20 min. The responses of the sensor to positive (SEB present, but no antibody on sensor), negative (SEB absent, antibody on sensor), and buffer (SEB absent, antibody on sensor) controls were -17 +/- 10 (n = 3), -9 +/- 5 (n = 3), and -6 +/- 12 (n = 18) Hz, respectively. Positive verification of SEB detection was confirmed by two methods: (1) low-pH buffer release caused increase in resonance frequency, and (2) second antibody binding to SEB attached to sensor that caused further resonance frequency decrease. The significance of these results is that PEMC sensors can reliably detect SEB at 10-100 fg (effective concentration of 2.5 and 25 fg/mL) in complex fluids without sample preparation or the use of labeled reagents.

摘要

利用压电激发的毫米级悬臂梁(PEMC)传感器,展示了一种灵敏且可靠的方法,用于检测缓冲液、苹果汁和牛奶中的模型毒素——葡萄球菌肠毒素B(SEB)。在添加了SEB的牛奶和苹果汁样品中,检测限分别为10 fg和100 fg。通过固定针对SEB的多克隆抗体来制备PEMC传感器(2 mm(2)),将其暴露于1 mL含有10 fg - 10 ng SEB的1%牛奶和苹果汁中。传感器对苹果汁中100 fg、1 pg和10 pg的SEB的响应,导致共振频率分别下降113±18(n = 4)、308±24(n = 4)和521±20(n = 2)Hz。在牛奶中,10 fg、100 fg、1 pg和10 pg的SEB导致共振频率分别下降126±18(n = 2)、143±35(n = 4)、310±32(n = 5)和557±25(n = 2)Hz。在最初的20分钟内观察到样品溶液中SEB的阳性检测结果。传感器对阳性对照(存在SEB,但传感器上无抗体)、阴性对照(不存在SEB,传感器上有抗体)和缓冲液对照(不存在SEB,传感器上有抗体)的响应分别为 - 17±10(n = 3)、 - 9±5(n = 3)和 - 6±12(n = 18)Hz。通过两种方法确认了SEB检测的阳性结果:(1)低pH缓冲液释放导致共振频率增加,(2)二抗与附着在传感器上的SEB结合导致共振频率进一步下降。这些结果的意义在于,PEMC传感器无需样品制备或使用标记试剂,就能在复杂流体中可靠地检测低至10 - 100 fg(有效浓度为2.5和25 fg/mL)的SEB。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验