Szczawińska M E, Thayer D W, Phillips J G
Department of Food Hygiene, Faculty of Veterinary Science, Agricultural University of Warsaw, Poland.
Int J Food Microbiol. 1991 Dec;14(3-4):313-24. doi: 10.1016/0168-1605(91)90123-7.
Mechanically deboned chicken meat was irradiated at 0, 1.25 and 2.50 kGy (Cesium 137) and inoculated with Salmonella dublin ATCC 15480, Salmonella enteritidis ATCC 9186 or Salmonella typhimurium ATCC 14028. Samples were then stored at 5 degrees C and 10 degrees C and were subjected to microbiological analysis directly after irradiation and inoculation (time 0), and after 24, 72, 120, 168 and 216 h of storage. Samples stored at 20 degrees C were examined at time 0 and after 6, 12 and 24 h of storage. Irradiation at 1.25 and 2.50 kGy caused an average reduction in bacterial levels of 2.23 and 3.44 logs, respectively. S. dublin, S. enteritidis and S. typhimurium showed very small, insignificant changes in numbers, during storage of meat for 9 days at 5 degrees C. The final populations of S. dublin and S. typhimurium in samples irradiated before inoculation and stored at 10 degrees C or 20 degrees C were greater than the equivalent populations in samples which had not been irradiated before inoculation. Reduction of indigenous microflora in mechanically deboned chicken meat by irradiation may create better conditions for the growth of salmonellae and may thus increase the risk of salmonellosis when accidental contamination and temperature abuse occur after a radiation treatment. Therefore, irradiated mechanically deboned chicken meat should be properly refrigerated and protected against contamination.
对机械去骨鸡肉用0、1.25和2.50千戈瑞(铯137)进行辐照,并接种都柏林沙门氏菌ATCC 15480、肠炎沙门氏菌ATCC 9186或鼠伤寒沙门氏菌ATCC 14028。然后将样品分别储存在5℃和10℃,在辐照和接种后(时间0)以及储存24、72、120、168和216小时后进行微生物分析。储存在20℃的样品在时间0以及储存6、12和24小时后进行检测。1.25和2.50千戈瑞的辐照分别使细菌水平平均降低2.23和3.44对数。在5℃下将肉储存9天期间,都柏林沙门氏菌、肠炎沙门氏菌和鼠伤寒沙门氏菌的数量变化非常小,无统计学意义。接种前辐照并储存在10℃或20℃的样品中,都柏林沙门氏菌和鼠伤寒沙门氏菌的最终菌量高于接种前未辐照的样品中的相应菌量。通过辐照减少机械去骨鸡肉中的固有微生物群落可能为沙门氏菌的生长创造更好的条件,因此当在辐射处理后发生意外污染和温度滥用时,可能会增加沙门氏菌病的风险。因此,辐照后的机械去骨鸡肉应妥善冷藏并防止污染。