Hori Yasutomo, Sato Shingo, Hoshi Fumio, Higuchi Sei-ichi
Department of Small Animal Internal Medicine, School of Veterinary Medicine, Kitasato University, 23-35-1 Higashi, Towada, Aomori 034-8628, Japan.
Am J Vet Res. 2007 Oct;68(10):1051-7. doi: 10.2460/ajvr.68.10.1051.
To evaluate tissue Doppler imaging (TDI) of the left ventricular (LV) free wall (FW) and ventricular septum (VS) as an indicator of LV systolic function in dogs.
7 healthy Beagles.
Doses of dobutamine (5 and 10 microg/kg/min) and esmolol (50 and 100 microg/kg/min) were infused into the LV of each dog. With each dose, heart rate; myocardial performance index (MPI); transmitral inflow and ejection time (determined via pulsed-wave Doppler [PWD] echocardiography); and FW and VS velocities of the mitral valve annulus (determined via TDI during systole [S'], early diastole [E'], and late diastole [A']) were assessed.
With each dose, dobutamine significantly increased heart rate and the first derivatives of LV pressure (+dP/dt and -dP/dt), whereas esmolol significantly decreased the +dP/dt and -dP/dt values, compared with baseline. Esmolol (100 microg/kg/min) significantly decreased the VS-TDI-derived S' velocity and FW-TDI-derived E' velocity; dobutamine significantly increased transmitral inflow and TDI velocities. Regression coefficient between VS-TDI-derived S' velocity and +dP/dt was higher than that between FW-TDI-derived S' velocity and +dP/dt. Compared with baseline, the PWD- and VS-TDI-derived MPI were significantly decreased by dobutamine and significantly increased by esmolol at each dose. Values of FW-TDI-derived MPI were higher than values derived via the other techniques. Correlation between +dP/dt and VS-TDI-derived MPI was greater than that between +dP/dt and FW-TDI- or PWD-derived MPI.
In healthy dogs, the VS-TDI-derived S' velocity and MPI appear to be reliable assessments for evaluating LV systolic function.
评估左心室(LV)游离壁(FW)和室间隔(VS)的组织多普勒成像(TDI)作为犬左心室收缩功能指标的情况。
7只健康的比格犬。
向每只犬的左心室内注入多巴酚丁胺(5和10微克/千克/分钟)和艾司洛尔(50和100微克/千克/分钟)。每次给药后,评估心率;心肌性能指数(MPI);二尖瓣血流和射血时间(通过脉冲波多普勒[PWD]超声心动图测定);以及二尖瓣环FW和VS速度(在收缩期[S']、舒张早期[E']和舒张晚期[A']通过TDI测定)。
每次给药后,与基线相比,多巴酚丁胺显著增加心率和左心室压力的一阶导数(+dP/dt和 -dP/dt),而艾司洛尔显著降低 +dP/dt和 -dP/dt值。艾司洛尔(100微克/千克/分钟)显著降低VS-TDI得出的S'速度和FW-TDI得出的E'速度;多巴酚丁胺显著增加二尖瓣血流和TDI速度。VS-TDI得出的S'速度与 +dP/dt之间的回归系数高于FW-TDI得出的S'速度与 +dP/dt之间的回归系数。与基线相比,多巴酚丁胺使每次给药时PWD和VS-TDI得出的MPI显著降低,而艾司洛尔使其显著增加。FW-TDI得出的MPI值高于通过其他技术得出的值。+dP/dt与VS-TDI得出的MPI之间的相关性大于 +dP/dt与FW-TDI或PWD得出的MPI之间的相关性。
在健康犬中,VS-TDI得出的S'速度和MPI似乎是评估左心室收缩功能的可靠指标。