Rodrigues Dina, Sá e Melo António, da Silva António Marinho, Carvalheiro Vítor, Manuel Otero
Unidade de Cardiologia Pediátrica e Serviço de Imagiologia, Hospitais da Universidade de Coimbra, Coimbra, Portugal.
Rev Port Cardiol. 2007 Jul-Aug;26(7-8):755-8.
We report our experience of seven patients referred to our hospital with foreign bodies embolized in the cardiovascular system, namely fragmented catheters and devices used in interventional techniques, which were retrieved by a percutaneous approach. The patients' ages ranged from 2 to 29 years, with a mean age of 17. The majority (57%) were male. The retrieval equipment used included a pigtail catheter, multipurpose catheter with hand-prepared snare, Amplatz gooseneck snare, nitinol multisnare set and basket catheter. The foreign bodies were successfully removed percutaneously in all cases, with no complications.
我们报告了7例转诊至我院的心血管系统异物栓塞患者的经验,这些异物为介入技术中使用的破碎导管和装置,均通过经皮方法取出。患者年龄从2岁至29岁不等,平均年龄为17岁。大多数(57%)为男性。所使用的取出设备包括猪尾导管、手工制作圈套器的多用途导管、Amplatz鹅颈圈套器、镍钛合金多圈套器套件和网篮导管。所有病例中的异物均通过经皮方法成功取出,无并发症发生。