Suppr超能文献

采用高效液相色谱-紫外二极管阵列和大气压化学电离质谱检测法测定番茄中苯甲酰脲类杀虫剂残留量。

Determination of benzoylurea insecticide residues in tomatoes by high-performance liquid chromatography with ultraviolet-diode array and atmospheric pressure chemical ionization-mass spectrometry detection.

作者信息

Markoglou Anastasios N, Bempelou Eleftheria D, Liapis Konstantinos S, Ziogas Basil N

机构信息

Agricultural University of Athens, Laboratory of Pesticide Science, Votanikos, 118 55 Athens, Greece.

出版信息

J AOAC Int. 2007 Sep-Oct;90(5):1395-401.

Abstract

A simple and sensitive method using high-performance liquid chromatography/ mass spectrometry (LC/MS) was developed and validated for simultaneous determination of 5 benzoylurea insecticides-diflubenzuron, triflumuron, teflubenzuron, lufenuron, and flufenoxuron-in tomatoes. Residues were successfully separated on a C18 column by methanol-water isocratic elution. Detection was carried out by an ultraviolet diode array detector (UV-DAD) coupled with a quadrupole mass spectrometer, using atmospheric pressure chemical ionization (APCI) in negative-ion mode. The main ions were the deprotonated molecules [M-H]- for triflumuron, and the anions formed by elimination of hydrofluoric acid [M-H-HF]- for diflubenzuron and flufenoxuron, and [M-2H-HF] for lufenuron and teflubenzuron. The calibration plots were linear for both detectors over the range 0.05 to 10 microg/mL, and the method presented good quality parameters. The limits of detection for standard solutions were 0.008-0.01 mg/L (equivalent to 0.08-0.1 ng injected) for both detectors, and the limits of quantification (LOQs) were approximately 10 times lower than national maximum residue levels (MRLs). Depending on the compound and the detector, the LOQ values ranged from 0.2 to 0.4 ng injected. The optimum LC-UV-DAD/APCI-MS conditions were applied to the analysis of benzoylureas in tomatoes. The obtained recoveries from fortified tomato samples (50 g), extracted with ethyl acetate and purified by solid-phase extraction on silica sorbent, were 88-100 and 92.9-105% for the UV-DAD and MS detectors, respectively, with precision values (relative standard deviations) of 2.9-11 and 3.7-14%, respectively. The method was applied to 12 tomato samples from local markets, and diflubenzuron and lufenuron were detected in only one sample at concentrations lower than the MRLs. The results indicate that the developed LC/MS method is accurate, precise, and sensitive for quantitative and qualitative analysis at low levels of benzoylureas required by legislation.

摘要

建立了一种简单灵敏的高效液相色谱/质谱联用(LC/MS)方法,用于同时测定番茄中的5种苯甲酰脲类杀虫剂——除虫脲、杀铃脲、氟铃脲、虱螨脲和氟虫脲。在C18柱上通过甲醇-水等度洗脱成功分离了残留。采用紫外二极管阵列检测器(UV-DAD)与四极杆质谱仪联用进行检测,在负离子模式下使用大气压化学电离(APCI)。主要离子为杀铃脲的去质子化分子[M-H]-,除虫脲和氟虫脲消除氢氟酸形成的阴离子[M-H-HF]-,以及虱螨脲和氟铃脲的[M-2H-HF]。两种检测器的校准曲线在0.05至10 μg/mL范围内均呈线性,该方法具有良好的质量参数。两种检测器对标准溶液的检测限均为0.008 - 0.01 mg/L(相当于进样0.08 - 0.1 ng),定量限(LOQs)比国家最大残留限量(MRLs)低约10倍。根据化合物和检测器的不同,进样的LOQ值范围为0.2至0.4 ng。将最佳的LC-UV-DAD/APCI-MS条件应用于番茄中苯甲酰脲类的分析。用乙酸乙酯从加标番茄样品(50 g)中提取并通过硅胶吸附剂固相萃取纯化后,UV-DAD和MS检测器的回收率分别为88 - 100%和92.9 - 105%,精密度值(相对标准偏差)分别为2.9 - 11%和3.7 - 14%。该方法应用于来自当地市场的12个番茄样品,仅在一个样品中检测到除虫脲和虱螨脲,其浓度低于MRLs。结果表明,所建立的LC/MS方法对于法规要求的低水平苯甲酰脲类的定量和定性分析准确、精密且灵敏。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验