The aim of this paper has been to investigate the cochlear function and the basic properties of otoacoustic emissions (OAEs) in patients with tinnitus using Spontaneous Otoacoustic Emissions (SOAEs) and Transitory Evoked Otoacoustic Emissions (TEOAEs).
We have analyzed the incidence, amplitude and spectral content of hearing thresholds, SOAEs and TEOAEs in a sample of 44 ears. We have measured incidence, intensity, frequency, number of peaks and amplitude of emission and their variability across frequency range from 500 to 5000 Hz. A correlation was determined between the OAEs results and the results obtained using hearing thresholds.
We have not found statistically significant differences at 500, 1000, 2000, 4000 and 8000 Hz frequencies neither at mean hearing thresholds between the sample of ears with tinnitus and the sample of ears without tinnitus. SOAEs were only present in 1 of the 44 ears tested (2.27%) and it was a 17 dB SPL amplitude peak at 2770 Hz frequency. TEOAEs, however, were displayed in some frequency in all the ears. We have compared TEOAEs parameters between the sample of ears with tinnitus and the sample of ears without tinnitus in 500, 1000, 2000, 4000 and 5000 Hz frequencies, and we have only found statistically significant differences at 4000 Hz, p = 0.02. Comparison of TEOAEs parameters between ears with tinnitus and ears without tinnitus in the same patient have only found statistically significant differences at 4000 Hz frequency, p = 0.011. In both cases there were not statistically significant differences at 500, 1000, 2000 and 5000 Hz frequencies nor at mean TEOAEs amplitudes for every group.
We have not found significant relations between tinnitus and OAEs registration.
本文旨在利用自发性耳声发射(SOAE)和瞬态诱发耳声发射(TEOAE)来研究耳鸣患者的耳蜗功能及耳声发射(OAE)的基本特性。
我们分析了44只耳样本中听力阈值、SOAE和TEOAE的发生率、幅度及频谱内容。我们测量了发射的发生率、强度、频率、峰值数量和幅度及其在500至5000赫兹频率范围内的变化。确定了OAE结果与使用听力阈值获得的结果之间的相关性。
在500、1000、2000、4000和8000赫兹频率处,耳鸣耳样本与无耳鸣耳样本之间的平均听力阈值均未发现统计学上的显著差异。在44只测试耳中,只有1只耳出现了SOAE(2.27%),它是一个频率为2770赫兹、幅度为17分贝声压级的峰值。然而,所有耳在某些频率上均显示出TEOAE。我们比较了耳鸣耳样本与无耳鸣耳样本在500、1000、2000、4000和5000赫兹频率处的TEOAE参数,仅在4000赫兹处发现了统计学上的显著差异,p = 0.02。在同一患者的耳鸣耳与无耳鸣耳之间比较TEOAE参数,仅在4000赫兹频率处发现了统计学上的显著差异,p = 0.011。在这两种情况下,在500、1000、2000和5000赫兹频率处以及每组平均TEOAE幅度上均未发现统计学上的显著差异。
我们未发现耳鸣与OAE记录之间存在显著关联。