Abstract

The optimal dark adaptation time of electroretinograms (ERG's) performed on conscious dogs were determined using a commercially available ERG unit with a contact lens electrode and a built-in light source (LED-electrode). The ERG recordings were performed on nine healthy Miniature Schnauzer dogs. The bilateral ERG's at seven different dark adaptation times at an intensity of 2.5 cd.s/m(2) was performed. Signal averaging (4 flashes of light stimuli) was adopted to reduce electrophysiologic noise. As the dark adaptation time increased, a significant increase in the mean a-wave amplitudes was observed in comparison to base-line levels up to 10 min (p < 0.05). Thereafter, no significant differences in amplitude occurred over the dark adaptation time. Moreover, at this time the mean amplitude was 60.30 +/- 18.47 microV. However, no significant changes were observed for the implicit times of the a-wave. The implicit times and amplitude of the b-wave increased significantly up to 20 min of dark adaptation (p < 0.05). Beyond this time, the mean b-wave amplitudes was 132.92 +/- 17.79 microV. The results of the present study demonstrate that, the optimal dark adaptation time when performing ERG's, should be at least 20 min in conscious Miniature Schnauzer dogs.

摘要

使用配备隐形眼镜电极和内置光源(发光二极管电极)的市售视网膜电图(ERG)设备,测定清醒犬的ERG最佳暗适应时间。对9只健康的迷你雪纳瑞犬进行ERG记录。在强度为2.5cd·s/m²的情况下,对7个不同暗适应时间进行双侧ERG检查。采用信号平均法(4次闪光刺激)以降低电生理噪声。随着暗适应时间增加,与基线水平相比,在长达10分钟时观察到平均a波振幅显著增加(p<0.05)。此后,在整个暗适应时间内振幅无显著差异。而且,此时平均振幅为60.30±18.47微伏。然而,a波的潜伏时间未观察到显著变化。b波的潜伏时间和振幅在暗适应长达20分钟时显著增加(p<0.05)。超过这个时间,平均b波振幅为132.92±17.79微伏。本研究结果表明,在清醒的迷你雪纳瑞犬中进行ERG检查时,最佳暗适应时间应至少为20分钟。

相似文献

2
Dark adaptation time in canine electroretinography using a contact lens electrode with a built-in light source.
J Vet Med Sci. 2015 Oct;77(10):1335-8. doi: 10.1292/jvms.14-0647. Epub 2015 Jun 13.
3
Effects of stimulus intensity for electroretinogram in conscious Miniature Schnauzers.
J Vet Med Sci. 2008 Aug;70(8):857-9. doi: 10.1292/jvms.70.857.
5
The effects of different anesthetic agents on short electroretinography protocol in dogs.
J Vet Med Sci. 2009 Jun;71(6):763-8. doi: 10.1292/jvms.71.763.
6
[Clinical electroretinography in the dog. Part 3].
Schweiz Arch Tierheilkd. 1992;134(2):61-74.
8
Electroretinography (ERG) in the wild giant panda (Ailuropoda melanoleuca).
Vet Ophthalmol. 2021 Mar;24(2):216-222. doi: 10.1111/vop.12857. Epub 2021 Jan 7.
9
Characterization of the normal dark adaptation curve of the horse.
Vet Ophthalmol. 2012 Jan;15(1):42-5. doi: 10.1111/j.1463-5224.2011.00923.x. Epub 2011 Jul 12.
10
[Oscillating potentials on the B-wave of the ERG in the dog].
Schweiz Arch Tierheilkd. 1992;134(9):431-43.

引用本文的文献

1
Horse vision through two lenses: Tinbergen's Four Questions and the Five Domains.
Front Vet Sci. 2025 Aug 14;12:1647911. doi: 10.3389/fvets.2025.1647911. eCollection 2025.
3
Anti-inflammatory α-Melanocyte-Stimulating Hormone Protects Retina After Ischemia/Reperfusion Injury in Type I Diabetes.
Front Neurosci. 2022 Feb 25;16:799739. doi: 10.3389/fnins.2022.799739. eCollection 2022.

本文引用的文献

1
Electroretinography using contact lens electrode with built-in light source in dogs.
J Vet Med Sci. 2005 May;67(5):509-14. doi: 10.1292/jvms.67.509.
2
Standard for clinical electroretinography (2004 update).
Doc Ophthalmol. 2004 Mar;108(2):107-14. doi: 10.1023/b:doop.0000036793.44912.45.
3
Flash electroretinography in standing horses using the DTL microfiber electrode.
Vet Ophthalmol. 2003 Mar;6(1):27-33. doi: 10.1046/j.1463-5224.2003.00261.x.
6
Guidelines for clinical electroretinography in the dog.
Doc Ophthalmol. 2002 Sep;105(2):83-92. doi: 10.1023/a:1020524305726.
7
Clinical electrophysiology in veterinary ophthalmology--the past, present and future.
Doc Ophthalmol. 2002 Jan;104(1):5-16. doi: 10.1023/a:1014463514302.
8
Contrast sensitivity in pigeons: a comparison of behavioral and pattern ERG methods.
Doc Ophthalmol. 2002 Jan;104(1):107-18. doi: 10.1023/a:1014427615636.
9
The electroretinogram and visual evoked potential of freely moving rats.
Brain Res Bull. 2001 Sep 1;56(1):7-14. doi: 10.1016/s0361-9230(01)00585-8.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验