Turkyilmaz Ilser, Avci Mehmet, Kuran Serkan, Ozbek Esma Nida
Department of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio 43218-2357, USA.
Clin Implant Dent Relat Res. 2007 Dec;9(4):222-7. doi: 10.1111/j.1708-8208.2007.00045.x.
Recent studies have showed that immediate/early loading of dental implants is a clinically feasible concept with results similar to those for standard two-stage procedures, especially in the mandible. However, there are only a few studies regarding the immediate/early loading of maxillary implants supporting single-tooth crowns.
The aim of this study was to compare the clinical and radiological outcomes of early- and delayed-loaded dental implants supporting single-tooth crowns in the maxilla.
Twenty-nine patients were consecutively treated between 2000 and 2002 with 59 Brånemark System MK III TiUnite implants (Nobel Biocare AB, Göteborg, Sweden) in the maxilla. Two groups were formed according to the loading protocols. In the test group, definitive implant-supported single crowns were delivered to 19 patients 6 weeks after the implant placement. In the control group, definitive implant-supported single crowns were delivered to 10 patients 6 months after the implant placement. Clinical and radiographic parameters were recorded at baseline, 1 to 4 years. Implant stability measurements have only been performed at 4-year follow-up recall.
Overall, three implants were lost during the study period. Two implants were lost in the test group including 36 implants, which indicated a survival rate of 94.4%. One of the lost implants was replaced and then osseointegrated successfully. One implant was lost in the control group during the healing period, which indicated a survival rate of 95.7%. The average marginal bone loss was 1.11 mm for 56 implants after 4 years. There were no significant differences in marginal bone levels, insertion torque, and resonance frequency values between the two groups.
The results of this study indicate that 6 weeks of early loading period for TiUnite-surface titanium implants in the maxilla is reliable and predictable for this patient population and may offer an alternative to the standard loading protocol.
近期研究表明,牙种植体即刻/早期负载在临床上是可行的概念,其结果与标准两阶段手术相似,尤其是在下颌骨。然而,关于上颌单颗牙冠支持种植体的即刻/早期负载的研究较少。
本研究旨在比较上颌单颗牙冠支持种植体早期负载和延迟负载的临床及影像学结果。
2000年至2002年期间,连续29例患者在上颌植入59枚Brånemark系统MK III TiUnite种植体(诺贝尔生物保健公司,瑞典哥德堡)。根据负载方案分为两组。试验组中,19例患者在种植体植入6周后安装最终的种植体支持单冠。对照组中,10例患者在种植体植入6个月后安装最终的种植体支持单冠。在基线、1至4年时记录临床和影像学参数。仅在4年随访复查时进行种植体稳定性测量。
总体而言,研究期间有3枚种植体脱落。试验组36枚种植体中有2枚脱落,存留率为94.4%。其中1枚脱落种植体被替换,随后成功实现骨结合。对照组在愈合期有1枚种植体脱落,存留率为95.7%。4年后,56枚种植体的平均边缘骨吸收为1.11 mm。两组在边缘骨水平、植入扭矩和共振频率值方面无显著差异。
本研究结果表明,上颌TiUnite表面钛种植体6周的早期负载期对该患者群体是可靠且可预测的,可能为标准负载方案提供一种替代方案。