Schäfer Andreas, van der Zwaag Wietske, Francis Susan T, Head Kay E, Gowland Penny A, Bowtell Richard W
Sir Peter Mansfield Magnetic Resonance Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, NG7 2RD, UK.
MAGMA. 2008 Mar;21(1-2):113-20. doi: 10.1007/s10334-007-0099-6. Epub 2007 Dec 18.
The sensitivity of spin echo (SE) experiments to blood oxygenation level dependent (BOLD) contrast was explored in a study of the same six subjects carried out at 3 and 7 T.
Multi-slice, single shot, spin echo, echo planar images with a voxel size of 1 x 1 x 3 mm3 were acquired at three different echo times, during execution of a simple motor task.
Significant activation was observed at all echo times at both field strengths. Analysis of the fractional signal change as a function of echo time indicated that the change in relaxation rate, Delta R2, at 7 T was -0.51 +/- 0.14 s (-1), which was 1.3 times larger than the value found at 3 T. Measurements of the percentage signal change on activation and temporal signal to noise ratio showed that there was an increase in the BOLD contrast to noise ratio (CNR) at 7 versus 3 T by a factor of 1.9. There was no overlap of areas of significant activation in the SE data acquired at either field strength with the site of large veins.
SE-BOLD CNR in motor cortex was found to increase significantly at 7 T compared with 3 T.
在一项针对6名受试者在3 T和7 T磁场下进行的研究中,探讨自旋回波(SE)实验对血氧水平依赖(BOLD)对比的敏感性。
在执行一项简单运动任务期间,于三个不同回波时间采集多层面、单次激发、自旋回波、回波平面图像,体素大小为1×1×3 mm3。
在两个场强下的所有回波时间均观察到显著激活。对分数信号变化作为回波时间函数的分析表明,7 T时的弛豫率变化ΔR2为-0.51±0.14 s-1,比3 T时的值大1.3倍。对激活时信号变化百分比和时间信号噪声比的测量表明,7 T时的BOLD对比噪声比(CNR)相对于3 T增加了1.9倍。在任一磁场强度下采集的SE数据中,显著激活区域与大静脉部位均无重叠。
发现运动皮层中的SE-BOLD CNR在7 T时比3 T时显著增加。