Changrue Viboon, Raghavan G S Vijaya, Gariépy Yvan, Orsat Valérie
Department of Bioresource Engineering, Macdonald Campus of McGill University, 21111 Lakeshore Road, Ste-Anne-de-Bellevue, QC, H9X 3V9, Canada.
J Microw Power Electromagn Energy. 2007;41(2):39-47.
A laboratory scale microwave vacuum dryer with the ability to record temporal variation of mass and temperature of a drying product was designed and built. The initial study was set up to investigate the effect of the position of a vacuum pressure control valve at two vacuum pressure levels, 6.5 and 13.3 kPa, with a fixed microwave power input of 1.5 W/g. Then, strawberry halves and carrot cubes (10 x 10 x 10 mm) were used for a preliminary study to investigate the effect on drying product temperature and the effect of input microwave powers (1, 1.5 and 2 W/g) at a fixed level of vacuum pressure (6.5 kPa). The position of the valve which allows air to pass through the vacuum container was found to provide shorter drying time and reduced the occurrence of water vapor condensation. The product temperature at the end stage of drying under continuous microwave mode was too high to ensure quality for both dried strawberry halves and carrot cubes.
设计并制造了一种实验室规模的微波真空干燥机,它能够记录干燥产品的质量和温度随时间的变化。最初的研究旨在考察在两种真空压力水平(6.5 kPa和13.3 kPa)下,真空压力控制阀位置的影响,微波功率输入固定为1.5 W/g。然后,使用草莓半块和胡萝卜块(10×10×10毫米)进行初步研究,以考察对干燥产品温度的影响以及在固定真空压力水平(6.5 kPa)下输入微波功率(1、1.5和2 W/g)的影响。发现允许空气通过真空容器的阀门位置可提供更短的干燥时间,并减少水蒸气凝结的发生。在连续微波模式下干燥末期的产品温度过高,无法确保干燥草莓半块和胡萝卜块的质量。