Ramoglu Sabri Ilhan, Usumez Serdar, Buyukyilmaz Tamer
Department of Orthodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.
Angle Orthod. 2008 Jan;78(1):140-4. doi: 10.2319/112106-473.1.
To test the null hypothesis that accelerated aging has no effect on the surface microhardness and roughness of two light-cured lingual retainer adhesives.
Ten samples of light-cured materials, Transbond Lingual Retainer (3M Unitek) and Light Cure Retainer (Reliance) were cured with a halogen light for 40 seconds. Vickers hardness and surface roughness were measured before and after accelerated aging of 300 hours in a weathering tester. Differences between mean values were analyzed for statistical significance using a t-test. The level of statistical significance was set at P < .05.
The mean Vickers hardness of Transbond Lingual Retainer was 62.8 +/- 3.5 and 79.6 +/- 4.9 before and after aging, respectively. The mean Vickers hardness of Light Cure Retainer was 40.3 +/- 2.6 and 58.3 +/- 4.3 before and after aging, respectively. Differences in both groups were statistically significant (P < .001). Following aging, mean surface roughness was changed from 0.039 microm to 0.121 microm and from 0.021 microm to 0.031 microm for Transbond Lingual Retainer and Light Cure Retainer, respectively. The roughening of Transbond Lingual Retainer with aging was statistically significant (P < .05), while the change in the surface roughness of Light Cure Retainer was not (P > .05).
Accelerated aging significantly increased the surface microhardness of both light-cured retainer adhesives tested. It also significantly increased the surface roughness of the Transbond Lingual Retainer.
检验加速老化对两种光固化舌侧保持器粘合剂的表面显微硬度和粗糙度无影响这一零假设。
将10个光固化材料样本,即Transbond舌侧保持器(3M Unitek)和光固化保持器(Reliance)用卤素灯固化40秒。在老化试验箱中进行300小时加速老化前后,测量维氏硬度和表面粗糙度。使用t检验分析平均值之间的差异有无统计学意义。统计学显著性水平设定为P < 0.05。
Transbond舌侧保持器老化前和老化后的平均维氏硬度分别为62.8±3.5和79.6±4.9。光固化保持器老化前和老化后的平均维氏硬度分别为40.3±2.6和58.3±4.3。两组差异均具有统计学意义(P < 0.001)。老化后,Transbond舌侧保持器和光固化保持器的平均表面粗糙度分别从0.039微米变为0.121微米和从0.021微米变为0.031微米。Transbond舌侧保持器老化后的表面粗糙度增加具有统计学意义(P < 0.05),而光固化保持器的表面粗糙度变化则无统计学意义(P > 0.05)。
加速老化显著提高了所测试的两种光固化保持器粘合剂的表面显微硬度,同时也显著增加了Transbond舌侧保持器的表面粗糙度。