Suppr超能文献

关于带有TE111型隔板腔的紧凑型氢脉泽的实验研究。

An experimental study for the compact hydrogen maser with a TE111 septum cavity.

作者信息

Wang Q, Zhai Z, Zhang W, Lin C

机构信息

Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030, P.R. China.

出版信息

IEEE Trans Ultrason Ferroelectr Freq Control. 2000;47(1):197-200. doi: 10.1109/58.818762.

Abstract

We have made experiments on our compact active hydrogen maser with the cylindrical TE111-mode septum cavity, which is almost one-half the conventional TE011-mode cavity in size. An inductive radiation signal was observed, but the maser did not produce self-oscillation. The system supports oscillation when the cavity is placed in an external feedback loop.

摘要

我们对配有圆柱形TE111模式隔片腔的紧凑有源氢脉泽进行了实验,该腔的尺寸几乎是传统TE011模式腔的一半。观察到了感应辐射信号,但该脉泽未产生自激振荡。当将该腔置于外部反馈回路中时,该系统支持振荡。

相似文献

1
An experimental study for the compact hydrogen maser with a TE111 septum cavity.
IEEE Trans Ultrason Ferroelectr Freq Control. 2000;47(1):197-200. doi: 10.1109/58.818762.
2
A new method to reduce frequency-temperature coefficient of sapphire-loaded cavities for compact hydrogen masers.
IEEE Trans Ultrason Ferroelectr Freq Control. 2010 Mar;57(3):583-6. doi: 10.1109/TUFFC.2010.1450.
3
Designs of a miniaturized sapphire-loaded cavity for spaceborne hydrogen masers.
IEEE Trans Ultrason Ferroelectr Freq Control. 2010 Mar;57(3):587-91. doi: 10.1109/TUFFC.2010.1451.
4
Designs of a microwave TE011 mode cavity for a space borne H-maser.
IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Oct;52(10):1638-43. doi: 10.1109/tuffc.2005.1561619.
5
Environmental factors and hydrogen maser frequency stability.
IEEE Trans Ultrason Ferroelectr Freq Control. 1999;46(3):745-51. doi: 10.1109/58.764861.
6
Research on an Active Hydrogen Maser Digital Circuit Control System Based on FPGA.
Sensors (Basel). 2023 Nov 15;23(22):9202. doi: 10.3390/s23229202.
7
Optics integrated compact cavity for rubidium atomic frequency standards.
Rev Sci Instrum. 2019 Aug;90(8):084701. doi: 10.1063/1.5098035.
8
Optimal design and validation of atom trapping and atomic storage time for active hydrogen maser.
Rev Sci Instrum. 2021 Feb 1;92(2):023202. doi: 10.1063/5.0037945.
9
A gravitationally lensed water maser in the early Universe.
Nature. 2008 Dec 18;456(7224):927-9. doi: 10.1038/nature07544.
10
Stable microwave coaxial cavity plasma system at atmospheric pressure.
Rev Sci Instrum. 2008 May;79(5):054702. doi: 10.1063/1.2918980.