Suppr超能文献

用于分析人血浆中短链肉碱的快速毛细管电泳电喷雾离子阱串联质谱法的优化

Optimization of a rapid capillary electrophoresis ESI-IT tandem mass spectrometry method for the analysis of short-chain carnitines in human plasma.

作者信息

Desiderio Claudia, De Rossi Antonella, Inzitari Rosanna, Mancinelli Angelo, Rossetti Diana Valeria, Castagnola Massimo, Messana Irene

机构信息

Istituto di Chimica del Riconoscimento Molecolare-Sez di Roma, Consiglio Nazionale delle Ricerche, c/o dell'Università Cattolica del Sacro Cuore, L.go F. Vito 1, 00168, Roma, Italy.

出版信息

Anal Bioanal Chem. 2008 Mar;390(6):1637-44. doi: 10.1007/s00216-008-1880-8. Epub 2008 Feb 9.

Abstract

A capillary electrophoresis (CE) method coupled to electrospray ionization ion trap tandem mass spectrometry (ESI-IT-MS/MS) is described for the rapid analysis of carnitine, acetylcarnitine, and propionylcarnitine in human plasma. Optimization of the procedure was achieved by a reduced sample pretreatment and after examining several physicochemical parameters that influence both the CE separation and the MS analytes detection. The analysis of total carnitine in human plasma after hydrolysis of short-chain metabolites is also shown. The analysis of carnitine and metabolites was obtained in less than 10 min using a 200 mM ammonium formate buffer, pH 2.5, with high sensitivity and specificity using the MS detection in product ion scan mode. The method was tested for quantitative recovery using dialyzed human plasma as matrix and showed linearity in the concentrations ranges 20-160, 1-32, and 0.25-8 microM for carnitine, acetylcarnitine, and propionylcarnitine with (squared) correlation coefficients of 0.9984, 0.9995, and 0.9991, respectively. The intraday and intermediate analysis repeatability and accuracy are within 15% of relative standard deviation (RSD) at low, medium, and high concentration and within/or slight exceeding 20% at the lower limit of quantitation (LLOQ). The method is sensitive for determining carnitine and its metabolites in human plasma with high specificity.

摘要

本文描述了一种毛细管电泳(CE)与电喷雾电离离子阱串联质谱(ESI-IT-MS/MS)联用的方法,用于快速分析人血浆中的肉碱、乙酰肉碱和丙酰肉碱。通过减少样品预处理,并考察了影响CE分离和MS分析物检测的几个物理化学参数,实现了该方法的优化。文中还展示了短链代谢物水解后人血浆中总肉碱的分析结果。使用200 mM甲酸铵缓冲液(pH 2.5),在产物离子扫描模式下进行MS检测,可在不到10分钟内完成肉碱及其代谢物的分析,具有高灵敏度和特异性。以透析后的人血浆为基质,对该方法进行了定量回收率测试,结果表明,肉碱、乙酰肉碱和丙酰肉碱在20 - 160、1 - 32和0.25 - 8 microM的浓度范围内呈线性,(平方)相关系数分别为0.9984、0.9995和0.9991。日内和日间分析的重复性和准确性在低、中、高浓度下的相对标准偏差(RSD)均在15%以内,在定量下限(LLOQ)时在20%以内/或略超过20%。该方法对人血浆中肉碱及其代谢物的测定具有高特异性和高灵敏度。