Li Yanyan, Wei Guohui, Hu Jia, Liu Xiujuan, Zhao Xinna, Wang Xuedong
School of Environmental Science and Public Health, Wenzhou Medical College, Wenzhou 325035, China.
Anal Chim Acta. 2008 May 12;615(1):96-103. doi: 10.1016/j.aca.2008.03.038. Epub 2008 Mar 27.
A simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME), has been developed for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) in water samples. The factors influencing microextraction efficiencies, such as the kind and volume of extraction and dispersive solvent, the extraction time and the salt effect, were optimized. Under the optimum conditions (sample volume: 5 mL; extraction solvent: tetrachloroethane, 20.0 microL; dispersive solvent: acetonitrile, 1.00 mL; extraction time: below 5s and without salt addition), the enrichment factors and extraction recoveries were high and ranged from 268 to 305 and 87.0 to 119.1%, respectively. Linearity was observed in the range 0.05-50 ng mL(-1) for BDE-28 and BDE-99, and 0.1-100 ng mL(-1) for BDE-47 and BDE-209, respectively. Coefficients of correlation (r(2)) ranged from 0.9995 to 0.9999. The repeatability study was carried out by extracting the spiked water samples at concentration levels of 50 ng mL(-1) for BDE-28 and BDE-99, and 100 ng mL(-1) for BDE-47 and BDE-209, respectively. The relative standard deviations (R.S.D.s) varied between 3.8 and 6.3% (n=5). The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.4 to 55.6 pg mL(-1) (the wavelength of detector at 226 nm). The relative recoveries of PBDEs from tap, lake water and landfill leachate samples at spiking levels of 5, 10 and 50 ng mL(-1) were in the range of 89.7-107.6%, 114.3-119.1% and 87.0-90.9%, respectively. As a result, this method can be successfully applied for the determination of PBDEs in landfill leachate and environmental water samples.
一种简单、快速且高效的方法——分散液液微萃取(DLLME)已被开发用于水样中多溴二苯醚(PBDEs)的萃取和预富集。对影响微萃取效率的因素,如萃取溶剂和分散溶剂的种类及体积、萃取时间和盐效应进行了优化。在最佳条件下(样品体积:5 mL;萃取溶剂:四氯乙烷,20.0 μL;分散溶剂:乙腈,1.00 mL;萃取时间:低于5 s且不添加盐),富集因子和萃取回收率较高,分别在268至305和87.0%至119.1%之间。BDE - 28和BDE - 99的线性范围分别为0.05 - 50 ng mL⁻¹,BDE - 47和BDE - 209的线性范围分别为0.1 - 100 ng mL⁻¹。相关系数(r²)在0.9995至0.9999之间。通过分别在浓度水平为50 ng mL⁻¹(针对BDE - 28和BDE - 99)以及100 ng mL⁻¹(针对BDE - 47和BDE - 209)下萃取加标水样进行重复性研究。相对标准偏差(R.S.D.s)在3.8%至6.3%之间(n = 5)。基于信噪比(S/N)为3的检测限(LODs)在12.4至55.6 pg mL⁻¹之间(检测器波长为226 nm)。在加标水平为5、10和50 ng mL⁻¹时,自来水中、湖水中和垃圾渗滤液样品中PBDEs的相对回收率分别在89.7%至107.6%、114.3%至119.1%和87.0%至90.9%之间。因此,该方法可成功应用于垃圾渗滤液和环境水样中PBDEs的测定。