Agthong Sithiporn, Chentanez Vilai, Koonam Junjira, Kaewsema Atitaya
Peripheral Nerve Research Unit, Department of Anatomy, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand.
Microsc Res Tech. 2008 Aug;71(8):585-7. doi: 10.1002/jemt.20590.
Morphometric analysis of nerve biopsy provides data of structural changes that are essential for early detection of peripheral neuropathy. Because of the laborious work associated with the total fiber quantification, various sampling methods have been introduced with controversial accuracy. Three-window sampling technique has been recently proposed to provide the accurate morphometric data of normal human sural nerve. However, its application in the diseased nerve has not been validated. This study, therefore, compared the morphometric data of nerve biopsies from 12 patients with various neuropathies obtained using this sampling method and those obtained by total fiber analysis. Total number, density, and diameter of myelinated fibers including myelin thickness and g ratio were analyzed. Intraclass correlation coefficients ranging from 0.95 to 0.99 indicate the high agreement between the data derived from the two methods in these parameters. This finding suggests the accuracy of the three-window sampling technique in the morphometric study of nerve with pathological alterations.
神经活检的形态计量分析可提供结构变化的数据,这些数据对于早期检测周围神经病变至关重要。由于与总纤维定量相关的工作繁琐,人们引入了各种采样方法,但其准确性存在争议。最近有人提出了三窗口采样技术,以提供正常人腓肠神经准确的形态计量数据。然而,其在患病神经中的应用尚未得到验证。因此,本研究比较了使用这种采样方法获得的12例各种神经病变患者神经活检的形态计量数据与通过总纤维分析获得的数据。分析了有髓纤维的总数、密度和直径,包括髓鞘厚度和g比值。组内相关系数在0.95至0.99之间,表明这两种方法得出的数据在这些参数上高度一致。这一发现表明三窗口采样技术在神经病理改变形态计量研究中的准确性。