Abstract

BACKGROUND

Cell death, as determined by complement-dependent cytotoxicity or antibody binding, as assessed by flow cytometry, are the two main methods histocompatibility laboratories use to identify HLA antibodies. Conventional cytotoxicity assays, even anti-human globulin (AHG) enhanced, are relatively insensitive, subjective and require complement fixation. In contrast, antibody binding assays (e.g.: flow cytometry crossmatch, FCXM) are sensitive, objective, and complement independent. When sera from potential transplant recipients test positive by both methods, most centers would not proceed to transplant unless patients undergo desensitization. However, when the CDC crossmatch is negative but the FCXM positive, how or whether to proceed is controversial. Frequently, both assays are performed.

METHODS

In this study, we developed a comprehensive procedure that determines cell death, and antibody binding in a single assay: the cytotoxic flow crossmatch (cFCXM). The assay was validated in parallel studies with two other conventional methodologies, namely AHG and FCXM.

RESULTS

Using a combination of eight cells and 15 sera, we have determined an optimal method for the simultaneous detection of HLA antibody binding and cytotoxicity using a single platform. Additionally, we have identified three distinct patterns of HLA antibody reactivity: (1) AHG(pos)/cFCXM(pos)/FCXM(pos), (2) AHG(neg)/cFCXM(neg)/FCXM(pos), and (3) a previously unrecognized category, namely, AHG(neg)/cFCXM(pos)/FCXM(pos).

CONCLUSIONS

These studies document that cytotoxicity and antibody binding can be simultaneously assessed and marks the first demonstration of complement-dependent HLA antibodies undetectable by conventional cytotoxicity. Routine application of this assay may provide new insights regarding transplantation of patients presenting as AHG(neg)/FCXM(pos) by classifying them according to their cFCXM status.

摘要

背景

通过补体依赖细胞毒性或抗体结合来确定细胞死亡,这两种方法是组织相容性实验室用于鉴定HLA抗体的主要方法,细胞死亡通过流式细胞术进行评估。传统的细胞毒性检测方法,即使是抗人球蛋白(AHG)增强的方法,也相对不敏感、主观且需要补体固定。相比之下,抗体结合检测方法(如流式细胞术交叉配型,FCXM)敏感、客观且不依赖补体。当潜在移植受者的血清通过两种方法检测均为阳性时,除非患者进行脱敏治疗,大多数中心不会进行移植。然而,当补体依赖细胞毒性交叉配型(CDC交叉配型)为阴性但FCXM为阳性时,如何处理或是否继续存在争议。通常,两种检测都会进行。

方法

在本研究中,我们开发了一种综合程序,可在单一检测中同时确定细胞死亡和抗体结合:细胞毒性流式交叉配型(cFCXM)。该检测方法在与另外两种传统方法(即AHG和FCXM)的平行研究中得到验证。

结果

使用8种细胞和15份血清的组合,我们确定了一种在单一平台上同时检测HLA抗体结合和细胞毒性的最佳方法。此外,我们确定了三种不同模式的HLA抗体反应性:(1)AHG(阳性)/cFCXM(阳性)/FCXM(阳性),(2)AHG(阴性)/cFCXM(阴性)/FCXM(阳性),以及(3)一个先前未被识别的类别,即AHG(阴性)/cFCXM(阳性)/FCXM(阳性)。

结论

这些研究证明细胞毒性和抗体结合可以同时评估,这标志着首次证明了传统细胞毒性检测无法检测到的补体依赖HLA抗体。该检测方法的常规应用可能通过根据其cFCXM状态对AHG(阴性)/FCXM(阳性)患者进行分类,为移植提供新的见解。

相似文献

1
Cytotoxicity and antibody binding by flow cytometry: a single assay to simultaneously assess two parameters.
Cytometry B Clin Cytom. 2008 Sep;74(5):287-94. doi: 10.1002/cyto.b.20424.
5
Crossmatching technique facilitating kidney transplantation.
J Med Assoc Thai. 1997 Sep;80 Suppl 1:S55-61.
8
Flow cytometric crossmatch for kidney transplantation.
J Med Assoc Thai. 2005 Jun;88(6):769-74.
9
Positive B-cell only flow cytometric crossmatch: implications for renal transplantation.
Exp Mol Pathol. 2008 Aug;85(1):59-63. doi: 10.1016/j.yexmp.2008.03.009. Epub 2008 Apr 10.
10
Improved graft survival for flow cytometry and antihuman globulin crossmatch-negative retransplant recipients.
Transplantation. 1990 Jan;49(1):52-6. doi: 10.1097/00007890-199001000-00011.

引用本文的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验