Avery Stephen, Ainsley Chris, Maughan Richard, McDonough James
Hospital of the University of Pennsylvania, 3400 Spruce St., 2 Donner, Philadelphia, PA 19104, USA.
Radiat Prot Dosimetry. 2008;131(2):167-79. doi: 10.1093/rpd/ncn136. Epub 2008 May 16.
The University of Pennsylvania is building a proton therapy facility in collaboration with Walter Reed Army Medical Center. The proposed facility has four gantry rooms, a fixed beam room and a research room, and will use a cyclotron as the source of protons. In this study, neutron shielding considerations for the proposed proton therapy facility were investigated using analytical techniques and Monte Carlo simulated neutron spectra. Neutron spectra calculations were done using the GEANT4 (v6.2) simulation code for various materials: water, carbon, iron, nickel and tantalum to estimate the neutron production at proton beam energies of 100, 175 and 250 MeV. Dose equivalent calculations were performed using analytical methods at various critical points within the facility, by folding the GEANT4 produced neutron spectra with dose equivalent rate data from the National Council on Radiation Protection and Measurements (NCRP) Report #144.
宾夕法尼亚大学正在与沃尔特·里德陆军医疗中心合作建设一个质子治疗设施。拟建的设施有四个旋转机架治疗室、一个固定束流治疗室和一个研究室,并将使用回旋加速器作为质子源。在本研究中,使用分析技术和蒙特卡罗模拟中子能谱对拟建质子治疗设施的中子屏蔽考虑因素进行了研究。使用GEANT4(v6.2)模拟代码对水、碳、铁、镍和钽等各种材料进行中子能谱计算,以估计在100、175和250 MeV质子束能量下的中子产生情况。通过将GEANT4产生的中子能谱与美国国家辐射防护与测量委员会(NCRP)第144号报告中的剂量当量率数据进行叠加,使用分析方法在设施内的各个关键点进行剂量当量计算。