Suppr超能文献

M型、脉冲组织多普勒和彩色组织多普勒在评估正常受试者二尖瓣环收缩期位移中的一致性。

Concordance between M-mode, pulsed Tissue Doppler, and colour Tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects.

作者信息

Ballo Piercarlo, Bocelli Arianna, Motto Andrea, Mondillo Sergio

机构信息

Cardiology Operative Unit, S. Andrea Hospital, via Veneto 197, 19100 La Spezia, Italy.

出版信息

Eur J Echocardiogr. 2008 Nov;9(6):748-53. doi: 10.1093/ejechocard/jen130. Epub 2008 Apr 2.

Abstract

AIMS

M-mode left atrioventricular plane displacement (AVPD) correlates with Tissue Doppler (TD) peak systolic annular velocity in healthy individuals. This approach is biased by several interacting factors related to the structural complexity of mitral annulus physiology, including the different dimensional values of measures, the confounding effect of isovolumic motions, and the spectral thickness of pulsed TD envelope. We sought to analyze the effective concordance between techniques in the assessment of systolic annular excursion.

METHODS AND RESULTS

In 92 healthy subjects (age 60.5 +/- 18.6, 43.5% women), systolic AVPD was measured after exclusion of isovolumic components using three techniques: (i) M-mode; (ii) temporal integration of pulsed TD systolic wave; and (iii) colour TD-derived tissue tracking. Close correlations of M-mode AVPD with pulsed TD velocity-time integral (VTI) (R = 0.90, P < 0.0001) and colour TD AVPD (R = 0.86, P < 0.0001) were found. However, M-mode AVPD underestimated pulsed TD VTI (mean error -5.1 +/- 1.7 mm) and overestimated colour TD AVPD (mean error 3.4 +/- 1.3 mm). The concordance between M-mode and pulsed TD increased after adjustment for spectral dispersion of pulsed TD instantaneous velocities (mean error 0.1 +/- 1.1 mm).

CONCLUSION

Despite strict correlations exist between M-mode and TD in the assessment of mitral annulus systolic excursion, the effective concordance between techniques is sub-optimal.

摘要

目的

在健康个体中,M 型左房室平面位移(AVPD)与组织多普勒(TD)收缩期峰值环速度相关。这种方法受到与二尖瓣环生理结构复杂性相关的几个相互作用因素的影响,包括测量的不同维度值、等容运动的混杂效应以及脉冲 TD 包络的频谱厚度。我们试图分析在评估收缩期环位移时技术之间的有效一致性。

方法与结果

在 92 名健康受试者(年龄 60.5±18.6 岁,43.5%为女性)中,使用三种技术在排除等容成分后测量收缩期 AVPD:(i)M 型;(ii)脉冲 TD 收缩波的时间积分;(iii)彩色 TD 衍生的组织追踪。发现 M 型 AVPD 与脉冲 TD 速度时间积分(VTI)密切相关(R = 0.90,P < 0.0001)以及与彩色 TD AVPD 密切相关(R = 0.86,P < 0.0001)。然而,M 型 AVPD 低估了脉冲 TD VTI(平均误差 -5.1±1.7 mm)并高估了彩色 TD AVPD(平均误差 3.4±1.3 mm)。在对脉冲 TD 瞬时速度的频谱离散进行调整后,M 型与脉冲 TD 之间的一致性增加(平均误差 0.1±1.1 mm)。

结论

尽管在评估二尖瓣环收缩期位移时 M 型和 TD 之间存在严格相关性,但技术之间的有效一致性并非最佳。