Determining the most advantageous size of liposuction cannula and injection needles in terms of adipocyte viability could help to increase fat graft survival. When recurrent injections are necessary, storing fat tissue which is harvested during the first operation could be a practical solution if it is stored at an appropriate temperature providing the highest amount of viable fat cells.
Fat tissue was removed from the abdomen of 10 consecutive female patients by 6-, 4- and 2-mm-diameter liposuction cannulas. Fat tissue harvested with the 6mm cannula was injected through 14, 16 and 20 g needles and collected in separate tubes. An additional three tubes of fat samples were prepared from fat tissue obtained with the 6mm cannula to be stored at +4, -20 and -80 degrees C for 2 weeks. Viability of the fat grafts was evaluated by fat cell isolation with collagenase digestion and staining with supravital dye and counting adipocytes with a haemocytometer.
The viability of fat grafts harvested with the 6mm cannula was higher than grafts obtained with smaller cannulas. The viability of fat grafts injected through 14, 16 and 20 g needles were similar to each other. The viability of fat grafts stored at +4 degrees C was similar to fresh tissue whereas freezing fat grafts caused significant loss of viable adipocytes compared to fresh tissue.
The use of larger liposuction cannulas for fat tissue harvesting provides more viable fat grafts. A temperature of +4 degrees C could be proposed as an effective and easily available way of storing fat grafts for at least 2 weeks.
就脂肪细胞活力而言,确定抽脂套管和注射针的最有利尺寸有助于提高脂肪移植的存活率。当需要反复注射时,如果将首次手术中采集的脂肪组织保存在能提供最大数量活脂肪细胞的适宜温度下,储存脂肪组织可能是一种切实可行的解决办法。
通过直径为6毫米、4毫米和2毫米的抽脂套管,从连续10名女性患者的腹部取出脂肪组织。用6毫米套管采集的脂肪组织通过14号、16号和20号针进行注射,并分别收集到试管中。另外从用6毫米套管获得的脂肪组织中制备三管脂肪样本,分别储存在4℃、-20℃和-80℃下2周。通过胶原酶消化分离脂肪细胞、用超活染料染色并用血细胞计数器对脂肪细胞进行计数来评估脂肪移植的活力。
用6毫米套管采集的脂肪移植的活力高于用较小套管获得的移植。通过14号、16号和20号针注射的脂肪移植的活力彼此相似。储存在4℃的脂肪移植的活力与新鲜组织相似,而与新鲜组织相比,冷冻脂肪移植导致活脂肪细胞显著损失。
使用较大的抽脂套管采集脂肪组织可提供更多有活力的脂肪移植。4℃的温度可被认为是储存脂肪移植至少2周的一种有效且易于实现的方法。