Abstract

A study of the equivalence to the reference methods of the Radiello samplers for ozone (O(3)) and benzene as well as the membrane-closed Palmes tube (MCPT) for nitrogen dioxide (NO(2)) is presented. These samplers benefit from new model equations capable of estimating their uptake rate. For O(3), the aim here was to demonstrate the equivalence for the reference period of 8 h and 120 microg m(-3), the target value of the 3rd European Daughter Directive. For benzene, the demonstration of equivalence to the annual limit value of 5 microg m(-3) of the 2nd European Daughter Directive was examined. In the case of NO(2), the equivalence to the annual limit value of the 1st European Daughter Directive (40 microg m(-3)) was considered. Results show that the radial sampler for O(3) fails to meet the Data Quality Objective (DQO) for continuous monitoring. However, with an expanded uncertainty of less than 30%, the O(3) diffusive sampler fulfils the DQO for indicative measurements. For benzene, the Radiello sampler exposed for 7 days gave satisfying results showing the ability of the sampler to meet the DQO of the reference method. Nevertheless, the field tests should be complemented by measurements for a wider range of benzene concentrations. In the case of NO(2), all the results of the laboratory and field experiments respected the requirements necessary for the demonstration of equivalence. Overall, these findings thus show that the Radiello sampler and the MCPT are equivalent to the reference methods only for assessment of benzene and NO(2), respectively.

摘要

本文介绍了Radiello臭氧(O₃)和苯采样器以及膜封闭帕尔默斯管(MCPT)二氧化氮(NO₂)与参考方法的等效性研究。这些采样器受益于能够估算其吸收速率的新模型方程。对于O₃,目的是证明在8小时和120微克/立方米的参考期内等效,这是第三个欧洲子指令的目标值。对于苯,研究了与第二个欧洲子指令5微克/立方米年度限值的等效性证明。在NO₂的情况下,考虑了与第一个欧洲子指令年度限值(40微克/立方米)的等效性。结果表明,O₃的径向采样器未能满足连续监测的数据质量目标(DQO)。然而,在扩展不确定度小于30%的情况下,O₃扩散采样器满足指示性测量的DQO。对于苯,暴露7天的Radiello采样器给出了令人满意的结果,表明该采样器有能力满足参考方法的DQO。尽管如此,现场测试应通过更广泛苯浓度范围的测量来补充。在NO₂的情况下,实验室和现场实验的所有结果都符合等效性证明所需的要求。总体而言,这些发现表明,Radiello采样器和MCPT仅分别在评估苯和NO₂时与参考方法等效。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验