Eichinger Walter B, Hettich Ina M, Ruzicka Daniel J, Holper Klaus, Schricker Carolin, Bleiziffer Sabine, Lange Ruediger
Department of Cardiovascular Surgery, German Heart Center Munich, Munich, Germany.
Ann Thorac Surg. 2008 Oct;86(4):1204-10. doi: 10.1016/j.athoracsur.2008.05.058.
The purpose of this study was to evaluate the long-term performance of the St. Jude Medical Biocor stented porcine prosthesis in the aortic position.
From January 1985 to December 1996, 455 patients admitted for aortic valve replacement were consecutively enrolled in this study. The mean age was 72.5 +/- 9 years, 18 patients (3.5%) had had previous cardiac surgery, and coronary artery bypass grafting was performed in 171 patients (37.6%). Follow-up was complete in 99.6%; up to 21 years were covered. Actuarial event-free rates are given as mean +/- standard error and adverse events were classified according to the guidelines for reporting morbidity and mortality after cardiac valvular operations.
Cumulative follow-up time was 3,321 patient-years with a mean follow-up of 8.2 years. The actuarial survival rate after 20 years was 9.4% +/- 2.8%. The actuarial rates for freedom from structural valve deterioration were 93.1% +/- 1.7% at 10 years, 88.4% +/- 3.5% at 15 years, and 70.3% +/- 10.9% at 20 years. The actuarial rates for freedom from reoperation due to structural valve deterioration were 91.9% +/- 1.6% at 10 years, 90.6% +/- 2.1% at 15 years, and 86.5% +/- 4.5% at 20 years.
This study presents one of the largest series of St. Jude Medical Biocor aortic valves in the world. Results indicate an age-dependent risk of structural valve degeneration beginning as soon as 7 years postoperatively for patients below the age of 65 years, but show a low overall incidence of valve-related complications and excellent durability.
本研究旨在评估圣犹达医疗公司的Biocor带支架猪主动脉瓣膜假体在主动脉位置的长期性能。
从1985年1月至1996年12月,连续纳入455例因主动脉瓣置换入院的患者。平均年龄为72.5±9岁,18例患者(3.5%)曾接受过心脏手术,171例患者(37.6%)接受了冠状动脉旁路移植术。随访完成率为99.6%;随访时间长达21年。精算无事件发生率以平均值±标准误差表示,不良事件根据心脏瓣膜手术后发病率和死亡率报告指南进行分类。
累积随访时间为3321患者年,平均随访8.2年。20年后的精算生存率为9.4%±2.8%。10年时无结构瓣膜退变的精算率为93.1%±1.7%,15年时为88.4%±3.5%,20年时为70.3%±10.9%。因结构瓣膜退变而再次手术的精算率在10年时为91.9%±1.6%,15年时为90.6%±2.1%,20年时为86.5%±4.5%。
本研究展示了世界上最大系列的圣犹达医疗公司Biocor主动脉瓣膜之一。结果表明,65岁以下患者术后7年就开始出现与年龄相关的结构瓣膜退变风险,但瓣膜相关并发症的总体发生率较低,耐久性良好。