Suppr超能文献

颈椎至头部中立位复位试验的重测信度。

Test-retest reliability of cervicocephalic relocation test to neutral head position.

作者信息

Pinsault Nicolas, Fleury Anthony, Virone Gilles, Bouvier Benjamin, Vaillant Jacques, Vuillerme Nicolas

机构信息

Laboratoire TIMC-IMAG, UMR UJF CNRS 5525, Grenoble, France.

出版信息

Physiother Theory Pract. 2008 Sep-Oct;24(5):380-91. doi: 10.1080/09593980701884824.

Abstract

Considering the important role of the cervical joint position sense on control of human posture and locomotion, accurate and reliable evaluation of neck proprioceptive abilities appears of great importance. Although the cervicocephalic relocation test (CRT) to the neutral head position (NHP) usually is used for both research and clinical purposes, its test-retest reliability has not been clearly established yet. The purpose of the present experiment was to 1) evaluate the test-retest reliability of the CRT to NHP and 2) to determine the number of trial recordings required to ensure reliable measurements. To this aim, 40 young healthy adults performed the CRT to NHP on two separate occasions. Ten trials were performed for each rotation side. Absolute and variable errors, processed along their horizontal, vertical, and global components, were used to assess the cervical joint repositioning accuracy and consistency, respectively. Mean difference between test and retest with 95% confidence interval, intraclass correlation coefficient, and Bland and Altman graphs with limits of agreement were used as statistical methods for assessing test-retest reliability. Results show that the CRT to NHP when executed in its original form (i.e., 10 trials) has a fair to excellent reliability (ICC ranged from 0.52 to 0.81 and from 0.49 to 0.77, for absolute and variable errors, respectively); the test-retest reliability of this test increases as the number of trials used to establish subject's repositioning errors increases; and using the mean of eight trials is sufficient to ensure fair to excellent reliability of the measurements (ICC ranged from 0.39 to 0.78 and from 0.44 to 0.78, for absolute and variable errors, respectively).

摘要

鉴于颈椎关节位置觉在人体姿势和运动控制中的重要作用,准确可靠地评估颈部本体感受能力显得至关重要。尽管通常将头颈部复位试验(CRT)用于中立头位(NHP)的研究和临床目的,但其重测信度尚未明确确立。本实验的目的是:1)评估CRT至NHP的重测信度;2)确定确保测量可靠所需的试验记录次数。为此,40名年轻健康成年人在两个不同时间进行了CRT至NHP试验。每个旋转方向进行10次试验。沿水平、垂直和整体分量处理的绝对误差和可变误差分别用于评估颈椎关节重新定位的准确性和一致性。用重测间的平均差异及其95%置信区间、组内相关系数以及带有一致性界限的Bland-Altman图作为评估重测信度的统计方法。结果表明,以原始形式(即10次试验)执行的CRT至NHP具有中等至优秀的信度(绝对误差和可变误差的组内相关系数分别为0.52至0.81和0.49至0.77);随着用于确定受试者重新定位误差的试验次数增加,该试验的重测信度提高;使用8次试验的平均值足以确保测量具有中等至优秀的信度(绝对误差和可变误差的组内相关系数分别为0.39至0.78和0.44至0.78)。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验