Suppr超能文献

介入治疗前后兔VX2软组织肿瘤血管生成的功能计算机断层扫描定量分析

Functional computed tomographic quantification of angiogenesis in rabbit VX2 soft-tissue tumor before and after interventional therapy.

作者信息

Zhang Jingfeng, Wang Renfa, Lou Haiyan, Zou Yu, Zhang Minming

机构信息

Department of Radiology, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.

出版信息

J Comput Assist Tomogr. 2008 Sep-Oct;32(5):697-705. doi: 10.1097/RCT.0b013e31815b7dcf.

Abstract

OBJECTIVE

Our purpose was to investigate the applicative value of multislice spiral computed tomography (CT) perfusion imaging on quantitative assessment of tumor angiogenesis before and after transcatheter arterial embolization and monitoring the early interventional therapeutic effect in malignant solid tumors.

METHODS

Sixteen New Zealand white rabbits successfully implanted VX2 tumor in the unilateral proximal thigh were divided into 2 groups (8 per group) at random and performed conventional CT plain scan and perfusion scan 14 days after implantation and 3 days after interventional therapy, respectively. The values of blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface area product (PS) in VX2 tumors and normal muscles were computed after intravenous bolus administration of iodinated contrast medium, and the differences among them were analyzed. Meanwhile, correlative analysis between perfusion parameters and microvessel density (MVD) counts and average optical density (AOD) of vascular endothelial growth factor (VEGF) was done.

RESULTS

Before interventional therapy, the values of BF, BV, MTT, and PS of the VX2 tumors in interventional group were 303.28 +/- 69.91 mL 100 g min, 7.02 +/- 3.10 mL 100 g, 1.99 +/- 0.28 seconds, and 65.88 +/- 9.38 mL 100 g min, respectively. Compared with the parametric values of normal muscular tissues, there were significant differences among them (F values were 4285.82, 1867.46, 413.04, and 698.42, respectively; P < 0.01). There were no significant differences of the above parametric values between the interventional group and the control group. Three days after interventional therapy, the values of BF, BV, MTT, and PS of the VX2 tumors in the interventional group were 7.53 +/- 2.37 mL 100 g min, 1.20 +/- 0.23 mL 100 g, 3.29 +/- 0.57 seconds, 4.01 +/- 1.51 mL 100 g min, respectively. Compared with the parametric values of preinterventional therapy and the control group, there were significant differences among them (P < 0.01). In addition, there was a good positive correlation between BF, BV, PS, and MVD, and AOD of VEGF (r > 0.7, P < 0.05) in VX2 tumors; however, there was no significant correlation between MTT and MVD (P > 0.05), and there was significant negative correlation between MTT and AOD of VEGF (r = -0.78, P < 0.05).

CONCLUSIONS

Multislice spiral CT perfusion imaging is a functional imaging technique that provides useful, quantitative assessment to tumor angiogenesis, blood perfusion, and vascular permeability, which can evaluate the early interventional therapeutic effect in malignant solid tumors invasively and accurately.

摘要

目的

探讨多层螺旋计算机断层扫描(CT)灌注成像在定量评估经导管动脉栓塞术前后恶性实体瘤肿瘤血管生成及监测早期介入治疗效果中的应用价值。

方法

16只成功在单侧大腿近端植入VX2肿瘤的新西兰白兔随机分为2组(每组8只),分别在植入后14天及介入治疗后3天进行常规CT平扫及灌注扫描。静脉团注碘化造影剂后计算VX2肿瘤及正常肌肉中的血流量(BF)、血容量(BV)、平均通过时间(MTT)和表面通透性乘积(PS)值,并分析它们之间的差异。同时,对灌注参数与微血管密度(MVD)计数及血管内皮生长因子(VEGF)的平均光密度(AOD)进行相关性分析。

结果

介入治疗前,介入组VX2肿瘤的BF、BV、MTT和PS值分别为303.28±69.91 mL/100 g/min、7.02±3.10 mL/100 g、1.99±0.28秒和65.88±9.38 mL/100 g/min。与正常肌肉组织的参数值相比,差异有统计学意义(F值分别为4285.82、1867.46、413.04和698.42;P<0.01)。介入组与对照组上述参数值差异无统计学意义。介入治疗后3天,介入组VX2肿瘤的BF、BV、MTT和PS值分别为7.53±2.37 mL/100 g/min、1.20±0.23 mL/100 g、3.29±0.57秒、4.01±1.51 mL/100 g/min。与介入治疗前及对照组的参数值相比,差异有统计学意义(P<0.01)。此外,VX2肿瘤中BF、BV、PS与MVD及VEGF的AOD之间存在良好的正相关(r>0.7,P<0.05);然而,MTT与MVD之间无显著相关性(P>0.05),MTT与VEGF的AOD之间存在显著负相关(r=-0.78,P<0.05)。

结论

多层螺旋CT灌注成像是一种功能成像技术,可对肿瘤血管生成、血流灌注和血管通透性进行有用的定量评估,能够有创且准确地评估恶性实体瘤的早期介入治疗效果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验