Suppr超能文献

通过免疫层析法检测阴道和尿液样本中的阴道毛滴虫抗原,并与培养法和显微镜检查法进行比较。

Trichomonas vaginalis antigens in vaginal and urine specimens by immunochromatography, compared to culture and microscopy.

作者信息

El-Moamly Amal M Abdul-Rasheed, Rashad Samir M

机构信息

Department of Parasitology, Faculty of Medicine, Suez Canal University, Ismailia, Egypt.

出版信息

J Egypt Soc Parasitol. 2008 Aug;38(2):573-84.

Abstract

This study evaluated the immunochromatographic (IC) capillary flow technology for detection of T. vaginalis antigens in vaginal and urine specimens. The IC antigen-detection test and microscopy wet smears were assessed against the InPouch TV culture. Vaginal-swabs and first-voided urine specimens were obtained from 348 sexually active symptomatic or asymptomatic, > or =16 years old women. Nineteen samples (5%) were positive by culture (95%, CI 0.3-0.8). The IC test (vaginal-specimens) was more sensitive than the wet smears. IC sensitivity was 84% (95%CI, 0.68-1.01), specificity 98% (95%CI, 0.96-0.99), positive predictive value (PPV) 70% (95%CI, 0.51-0.88), negative predictive value (NPV) 99% (95%CI, 0.98-1), (positive likelihood ratio (+LR): 39.6, and negative likelihood ratio (-LR) 0.2. The IC test using urine as a substrate had less performance than both microscopy and IC test of vaginal specimens. Urine-IC sensitivity was 53% (95%CI, 0.30-0.75), specificity 99% (95% CI, 0.98-1.00), PPV 77% (95%CI, 0.54-1), NPV 97% (95%CI, 0.96-0.99), +LR: 57.7, and -LR: 0.5. Sensitivity of vaginal smear was 68% (95%CI, 0.48-0.89), specificity 100%, PPV 100% (95% CI, 1), NPV 98% (95% CI, 0.97-1), +LR>225, & -LR: 0.3. T. vaginalis was diagnosed in two wet urine samples, but not in smears. The IC antigen improved T. vaginalis diagnosis, especially in screening, rapid, or point-of-care test, but in urine was less reliable than with vaginal smear.

摘要

本研究评估了免疫层析(IC)毛细管流动技术用于检测阴道和尿液标本中阴道毛滴虫抗原的情况。将IC抗原检测试验和显微镜湿涂片与InPouch TV培养法进行了对比评估。从348名年龄≥16岁、有性活动的有症状或无症状女性中获取了阴道拭子和首次晨尿标本。19份样本(5%)培养呈阳性(95%置信区间,0.3 - 0.8)。IC试验(阴道标本)比湿涂片更敏感。IC试验的敏感性为84%(95%置信区间,0.68 - 1.01),特异性为98%(95%置信区间,0.96 - 0.99),阳性预测值(PPV)为70%(95%置信区间,0.51 - 0.88),阴性预测值(NPV)为99%(95%置信区间,0.98 - 1),阳性似然比(+LR)为39.6,阴性似然比(-LR)为0.2。以尿液为底物的IC试验的性能不如阴道标本的显微镜检查和IC试验。尿液IC试验的敏感性为53%(95%置信区间),0.30 - 0.75),特异性为99%(95%置信区间,0.98 - 1.00),PPV为77%(95%置信区间,0.54 - 1),NPV为97%(95%置信区间,0.96 - 0.99),+LR为57.7,-LR为0.5。阴道涂片的敏感性为68%(95%置信区间,0.48 - 0.89),特异性为100%,PPV为100%(95%置信区间,1),NPV为98%(95%置信区间,0.97 - 1),+LR>225,-LR为0.3。在两份尿液湿标本中诊断出阴道毛滴虫,但在涂片中未诊断出。IC抗原改善了阴道毛滴虫的诊断,尤其是在筛查、快速或即时检验方面,但在尿液中不如阴道涂片可靠。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验