OBJECTIVE

To evaluate the association between poststenting atherosclerotic plaque redistribution/lumen reduction at the stent edge and stent length.

METHODS

Seventy stents were implanted to 47 patients with stable or unstable angina and 33 stents were < or = 18 mm and 37 stents were > 18 mm. Intravascular ultrasound analysis was performed on proximal stent edge, stent area and distal stent edge. Lumen area (LA) and vascular area (VA) were measured and lumen volume (LV) and vascular volume (VV) were calculated on the three segments. Vascular wall volume (WV) was calculated as VV-LV, volume of plaque redistribution = poststenting WV-prestenting WV.

RESULTS

Compared to prestenting, poststenting LV significantly decreased, VV remained unchanged and WV significantly increased at proximal and distal edges of < or = 18 mm group and at proximal edge of > 18 mm group, suggesting reduced lumen due to plaque distribution. At distal edge of > 18 mm group, poststenting LV, VV and WV all equally significantly increased therefore the lumen was not affected by plaque distribution.

CONCLUSION

The poststenting lumen changes due to plaque redistribution were associated with stent length, lumen reduced at proximal and distal edge of short stents and proximal edge of long stents but not at the distal edge of long stents.