Suppr超能文献

使用多参数磁共振成像体外测定骨关节炎中人类关节软骨的生物力学特性

In vitro determination of biomechanical properties of human articular cartilage in osteoarthritis using multi-parametric MRI.

作者信息

Juras Vladimir, Bittsansky Michal, Majdisova Zuzana, Szomolanyi Pavol, Sulzbacher Irene, Gäbler Stefan, Stampfl Jürgen, Schüller Georg, Trattnig Siegfried

机构信息

MR Center, Highfield MR, Department of Radiology, Medical University of Vienna, Lazarettgasse 14, 1090 Vienna, Austria.

出版信息

J Magn Reson. 2009 Mar;197(1):40-7. doi: 10.1016/j.jmr.2008.11.019. Epub 2008 Dec 8.

Abstract

The objective of this study was to evaluate the correlations between MR parameters and the biomechanical properties of naturally degenerated human articular cartilage. Human cartilage explants from the femoral condyles of patients who underwent total knee replacement were evaluated on a micro-imaging system at 3T. To quantify glycosaminoglycan (GAG) content, delayed gadolinium-enhanced MRI of the cartilage (dGEMRIC) was used. T(2) maps were created by using multi-echo, multi-slice spin echo sequences with six echoes: 15, 30, 45, 60, 75, and 90 ms. Data for apparent diffusion constant (ADC) maps were obtained from pulsed gradient spin echo (PGSE) sequences with five b-values: 10.472, 220.0, 627.0, 452.8, 724.5, and 957.7. MR parameters were correlated with mechanical parameters (instantaneous (I) and equilibrium (Eq) modulus and relaxation time (tau)), and the OA stage of each cartilage specimen was determined by histological evaluation of hematoxylin-eosin stained slices. For some parameters, a high correlation was found: the correlation of T(1Gd) vs Eq (r=0.8095), T(1Gd) vs I/Eq (r=-0.8441) and T(1Gd) vs tau (r=0.8469). The correlation of T(2) and ADC with selected biomechanical parameters was not statistically significant. In conclusion, GAG content measured by dGEMRIC is highly related to the selected biomechanical properties of naturally degenerated articular cartilage. In contrast, T(2) and ADC were unable to estimate these properties. The results of the study imply that some MR parameters can non-invasively predict the biomechanical properties of degenerated articular cartilage.

摘要

本研究的目的是评估磁共振成像(MR)参数与自然退变的人关节软骨生物力学特性之间的相关性。对接受全膝关节置换术患者股骨髁的人软骨外植体在3T的微观成像系统上进行评估。为了量化糖胺聚糖(GAG)含量,采用了软骨延迟钆增强磁共振成像(dGEMRIC)。通过使用具有六个回波(15、30、45、60、75和90毫秒)的多回波、多层自旋回波序列创建T(2)图。表观扩散系数(ADC)图的数据来自具有五个b值(10.472、220.0、627.0、452.8、724.5和957.7)的脉冲梯度自旋回波(PGSE)序列。MR参数与力学参数(瞬时(I)和平衡(Eq)模量以及弛豫时间(tau))相关,并且通过苏木精-伊红染色切片的组织学评估确定每个软骨标本的骨关节炎(OA)阶段。对于一些参数,发现了高度相关性:T(1Gd)与Eq的相关性(r = 0.8095)、T(1Gd)与I/Eq的相关性(r = -0.8441)以及T(1Gd)与tau的相关性(r = 0.8469)。T(2)和ADC与选定生物力学参数的相关性无统计学意义。总之,通过dGEMRIC测量的GAG含量与自然退变关节软骨的选定生物力学特性高度相关。相比之下,T(2)和ADC无法估计这些特性。该研究结果表明,一些MR参数可以无创地预测退变关节软骨的生物力学特性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验