Wu Xing, Zhou Cheng, Huang Wei-Jin, Qi Zi-Bai, Liang Zheng-Lun, Li He-Min, Zhuang Hui
National Institute for the Control of Pharmaceutical and Biological Products, Beijing 100050, China.
Zhonghua Liu Xing Bing Xue Za Zhi. 2008 Sep;29(9):915-8.
To compare and analyze the sensitivity, specificity of 4 domestic ELISA kits for detection of hepatitis B virus (HBV) markers (HBsAg, anti-HBs, HBeAg, anti-HBe, and anti-HBc).
Five hundred and ninety four serum samples collected from patients with chronic hepatitis B and abnormal blood donors were detected for HBV markers and by 4 domestic ELISA kits. Samples with conflicting results by different diagnostic kits were retested. Samples with the HBsAg values close to the cut-off point were detected by Abbott HBsAg confirmation kit (Architect HBsAg confirm). Sensitivity of the kits was determined, using the national sensitivity reference panels for HBsAg, anti-HBs, HBeAg, anti-HBe and anti-HBc.
The rates of sensitivity on 4 domestic kits for detection of HBsAg were 4 to 10 times lower, and on the 4 domestic kits for detection of anti-HBs, HBeAg, anti-HBe and anti-HBc were 4 to 16 times lower, as compared to Abbott Architect kits. In addition, the domestic HBV ELISA kits had some false positive results. The total coincidence rates of HBsAg, anti-HBs, HBeAg, anti-HBe, anti-HBc were 96.46%-98.15%, 94.28%-98.15%, 98.15%-99.49%, 90.07%-96.30%, 92.09%-96.80%, respectively.
Both sensitivity and specificity of the domestically produced HBV ELISA kits should be improved.
比较分析4种国产酶联免疫吸附测定(ELISA)试剂盒检测乙型肝炎病毒(HBV)标志物(HBsAg、抗-HBs、HBeAg、抗-HBe和抗-HBc)的灵敏度和特异性。
收集594份慢性乙型肝炎患者血清样本及血液检测异常的献血者血清样本,用4种国产ELISA试剂盒检测HBV标志物。对不同诊断试剂盒结果冲突的样本进行重新检测。对HBsAg值接近临界值的样本,采用雅培HBsAg确认试剂盒(Architect HBsAg confirm)进行检测。使用国家HBsAg、抗-HBs、HBeAg、抗-HBe和抗-HBc灵敏度参考品确定试剂盒的灵敏度。
与雅培Architect试剂盒相比,4种国产试剂盒检测HBsAg的灵敏度低4至10倍,检测抗-HBs、HBeAg、抗-HBe和抗-HBc的灵敏度低4至16倍。此外,国产HBV ELISA试剂盒存在一些假阳性结果。HBsAg、抗-HBs、HBeAg、抗-HBe、抗-HBc的总符合率分别为96.46%-98.15%、94.28%-98.15%、98.15%-99.49%、90.07%-96.30%、92.09%-96.80%。
国产HBV ELISA试剂盒的灵敏度和特异性均有待提高。