Suppr超能文献

采用高约束投影重建(HYPR)的桡动脉滑动窗口磁共振血管造影(MRA)。

Radial sliding-window magnetic resonance angiography (MRA) with highly-constrained projection reconstruction (HYPR).

作者信息

Jeong Hyun J, Cashen Ty A, Hurley Michael C, Eddleman Christopher, Getch Christopher, Batjer H Hunt, Carroll Timothy J

机构信息

Department of Biomedical Engineering, Northwestern University, Chicago, Illinois 60611, USA.

出版信息

Magn Reson Med. 2009 May;61(5):1103-13. doi: 10.1002/mrm.21888.

Abstract

Sufficient temporal resolution is required to image the dynamics of blood flow, which may be critical for accurate diagnosis and treatment of various intracranial vascular diseases, such as arteriovenous malformations (AVMs) and aneurysms. Highly-constrained projection reconstruction (HYPR) has recently become a technique of interest for high-speed contrast-enhanced magnetic resonance angiography (CE-MRA). HYPR provides high frame rates by preferential weighting of radial projections while maintaining signal-to-noise ratio (SNR) by using a high SNR composite. An analysis was done to quantify the effects of HYPR on SNR, contrast-to-noise ratio (CNR), and temporal blur compared to the previously developed radial sliding-window technique using standard filtered backprojection or regridding methods. Computer simulations were performed to study the effects of HYPR processing on image error and the temporal information. Additionally, in vivo imaging was done on patients with angiographically confirmed AVMs to measure the effects of alteration of various HYPR parameters on SNR as well as the fidelity of the temporal information. The images were scored by an interventional radiologist in a blinded read and were compared with X-ray digital subtraction angiography (DSA). It was found that with the right choice of parameters, modest improvements in both SNR and dynamic information can be achieved as compared to radial sliding-window MRA.

摘要

需要足够的时间分辨率来成像血流动力学,这对于准确诊断和治疗各种颅内血管疾病(如动静脉畸形(AVM)和动脉瘤)可能至关重要。高度约束投影重建(HYPR)最近已成为高速对比增强磁共振血管造影(CE-MRA)中一项受关注的技术。HYPR通过对径向投影进行优先加权来提供高帧率,同时通过使用高信噪比合成来保持信噪比(SNR)。与先前使用标准滤波反投影或重网格化方法开发的径向滑动窗口技术相比,进行了一项分析以量化HYPR对信噪比、对比噪声比(CNR)和时间模糊的影响。进行了计算机模拟以研究HYPR处理对图像误差和时间信息的影响。此外,对血管造影证实患有AVM的患者进行了体内成像,以测量各种HYPR参数的改变对信噪比以及时间信息保真度的影响。图像由介入放射科医生在盲法阅读中进行评分,并与X射线数字减影血管造影(DSA)进行比较。结果发现,通过正确选择参数,与径向滑动窗口MRA相比,信噪比和动态信息都能得到适度改善。

相似文献

2
PC HYPR flow: a technique for rapid imaging of contrast dynamics.
J Magn Reson Imaging. 2010 Feb;31(2):447-56. doi: 10.1002/jmri.22035.
10
Myocardial perfusion MRI with sliding-window conjugate-gradient HYPR.
Magn Reson Med. 2009 Oct;62(4):835-9. doi: 10.1002/mrm.22059.

引用本文的文献

1
Intracranial 3D and 4D MR Angiography Using Arterial Spin Labeling: Technical Considerations.
Magn Reson Med Sci. 2020 Dec 1;19(4):294-309. doi: 10.2463/mrms.rev.2019-0096. Epub 2019 Nov 22.
2
Self-calibrated interpolation of non-Cartesian data with GRAPPA in parallel imaging.
Magn Reson Med. 2020 May;83(5):1837-1850. doi: 10.1002/mrm.28033. Epub 2019 Nov 13.
4
Recent advances in 3D time-resolved contrast-enhanced MR angiography.
J Magn Reson Imaging. 2015 Jul;42(1):3-22. doi: 10.1002/jmri.24880. Epub 2015 Jun 1.
7
Combined renal MRA and perfusion with a single dose of contrast.
Magn Reson Imaging. 2012 Jul;30(6):878-85. doi: 10.1016/j.mri.2011.12.027. Epub 2012 Apr 20.
8
Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography.
J Magn Reson Imaging. 2012 Jul;36(1):249-58. doi: 10.1002/jmri.23630. Epub 2012 Feb 22.

本文引用的文献

1
4D radial contrast-enhanced MR angiography with sliding subtraction.
Magn Reson Med. 2007 Nov;58(5):962-72. doi: 10.1002/mrm.21364.
3
Time-resolved MR angiography with limited projections.
Magn Reson Med. 2007 Aug;58(2):316-25. doi: 10.1002/mrm.21312.
4
Characterizing radial undersampling artifacts for cardiac applications.
Magn Reson Med. 2006 Feb;55(2):396-403. doi: 10.1002/mrm.20782.
5
Highly constrained backprojection for time-resolved MRI.
Magn Reson Med. 2006 Jan;55(1):30-40. doi: 10.1002/mrm.20772.
8
Generalized autocalibrating partially parallel acquisitions (GRAPPA).
Magn Reson Med. 2002 Jun;47(6):1202-10. doi: 10.1002/mrm.10171.
10
Contrast-enhanced 3D MRA using SENSE.
J Magn Reson Imaging. 2000 Nov;12(5):671-7. doi: 10.1002/1522-2586(200011)12:5<671::aid-jmri3>3.0.co;2-f.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验