Abstract

BACKGROUND

The tools for measuring the congruence angle with digital radiography software can be difficult to use; therefore, the authors sought to develop a new, easy, and reliable method for measuring patellofemoral congruence. The abstract goes here and covers two columns.

HYPOTHESIS

The abstract goes The linear displacement measurement will correlate well with the congruence angle measurement. here and covers two columns.

STUDY DESIGN

Cohort study (diagnosis); Level of evidence, 2.

METHODS

On Merchant view radiographs obtained digitally, the authors measured the congruence angle and a new linear displacement measurement on preoperative and postoperative radiographs of 31 patients who suffered unilateral patellar dislocations and 100 uninjured subjects. The linear displacement measurement was obtained by drawing a reference line across the medial and lateral trochlear facets. Perpendicular lines were drawn from the depth of the sulcus through the reference line and from the apex of the posterior tip of the patella through the reference line. The distance between the perpendicular lines was the linear displacement measurement. The measurements were obtained twice at different sittings. The observer was blinded as to the previous measurements to establish reliability. Measurements were compared to determine whether the linear displacement measurement correlated with congruence angle.

RESULTS

Intraobserver reliability was above r(2) = .90 for all measurements. In patients with patellar dislocations, the mean congruence angle preoperatively was 33.5 degrees , compared with 12.1 mm for linear displacement (r(2) = .92). The mean congruence angle postoperatively was 11.2 degrees, compared with 4.0 mm for linear displacement (r(2) = .89). For normal subjects, the mean congruence angle was -3 degrees and the mean linear displacement was 0.2 mm.

CONCLUSION

The linear displacement measurement was found to correlate with congruence angle measurements and may be an easy and useful tool for clinicians to evaluate patellofemoral congruence objectively.

摘要

背景

使用数字放射成像软件测量吻合角的工具可能难以操作;因此,作者试图开发一种新的、简便且可靠的测量髌股关节吻合度的方法。摘要如下,占两栏篇幅。

假设

摘要如下,占两栏篇幅。线性位移测量与吻合角测量将具有良好的相关性。

研究设计

队列研究(诊断);证据等级,2级。

方法

在数字化获取的Merchant位X线片上,作者对31例单侧髌骨脱位患者和100例未受伤受试者的术前和术后X线片测量了吻合角和一种新的线性位移测量值。线性位移测量是通过在内外侧滑车关节面画一条参考线获得的。从沟的深度穿过参考线以及从髌骨后尖的顶点穿过参考线画出垂直线。垂直线之间的距离就是线性位移测量值。在不同时间进行了两次测量。观察者对之前的测量结果不知情以确定可靠性。比较测量值以确定线性位移测量是否与吻合角相关。

结果

所有测量的观察者内可靠性均高于r(2)=0.90。在髌骨脱位患者中,术前平均吻合角为33.5度,线性位移为12.1毫米(r(2)=0.92)。术后平均吻合角为11.2度,线性位移为4.0毫米(r(2)=0.89)。对于正常受试者,平均吻合角为-3度,平均线性位移为0.2毫米。

结论

发现线性位移测量与吻合角测量相关,可能是临床医生客观评估髌股关节吻合度的一种简便且有用的工具。

文献AI研究员