Suppr超能文献

激活起源、导联数量和导联配置对心脏移植排斥反应无创电生理检测的影响。

Influence of activation origin, lead number, and lead configuration on the noninvasive electrophysiologic detection of cardiac allograft rejection.

作者信息

Pirolo J S, Tweddell J S, Brunt E M, Pyo R, Shuman T S, Cox J L, Ferguson T B

机构信息

Division of Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, MO 63110.

出版信息

Circulation. 1991 Nov;84(5 Suppl):III344-54.

PMID:1934429
Abstract

An improved method of cardiac allograft surveillance, less invasive than endomyocardial biopsy (EMB), is required as the scope of cardiac transplantation increases. The correlation between changes in telemetrically recorded intramyocardial electrograms and the degree of rejection was examined. The electrophysiological parameter assessed was the unipolar peak-to-peak amplitude (UPPA), defined as the magnitude of the first, fast negative deflection of the QRS complex in unipolar electrograms. A canine model of intrathoracic heterotopic cardiac transplantation was employed in which each graft was instrumented with four unipolar intramyocardial electrodes (two left ventricle [LV] and two right ventricle [RV]) connected to two telemetric pacemakers. Immunosuppression was begun at operation and continued for a variable period of time following the acquisition of control data (postoperative days 6-10). Graft status was monitored via biweekly EMB. Intramyocardial electrograms were recorded from each lead during sinus rhythm and 36 atrial and ventricular pacing protocols on a daily basis. The daily UPPA was calculated for each rhythm sequence and expressed as percent of control UPPA. EMBs were qualitatively graded and assigned a quantitative rejection score (0 = none; 3 = severe). Criteria for rejection were rejection score (RS) greater than or equal to 0.66 or daily UPPA less than 85% control. Eight animals were included for study and, in all animals, rejection was documented. A total of 30 EMBs were obtained; in 11 EMBs rejection was present by histological criteria. Analysis of grouped UPPA data from all four leads revealed a sensitivity and specificity of 91% and 84%, respectively, in the detection of rejection. Analysis of grouped sinus UPPA data from the two LV leads revealed a sensitivity of 94% and 91%, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

随着心脏移植范围的扩大,需要一种比心内膜心肌活检(EMB)侵入性更小的心脏同种异体移植监测改进方法。研究了遥测记录的心肌电图变化与排斥反应程度之间的相关性。评估的电生理参数是单极峰峰值幅度(UPPA),定义为单极电图中QRS复合波第一个快速负向偏转的幅度。采用胸腔内异位心脏移植犬模型,每个移植物都安装有四个单极心肌内电极(两个左心室[LV]和两个右心室[RV]),连接到两个遥测起搏器。在手术时开始免疫抑制,并在获取对照数据(术后第6 - 10天)后持续不同时间段。通过每两周一次的EMB监测移植物状态。每天在窦性心律以及36种心房和心室起搏方案期间从每个导联记录心肌电图。计算每个心律序列的每日UPPA,并表示为对照UPPA的百分比。EMB进行定性分级并分配定量排斥评分(0 =无;3 =严重)。排斥标准为排斥评分(RS)大于或等于0.66或每日UPPA小于对照的85%。纳入8只动物进行研究,所有动物均记录到排斥反应。共获得30次EMB;11次EMB根据组织学标准存在排斥反应。对来自所有四个导联的分组UPPA数据进行分析显示,检测排斥反应的敏感性和特异性分别为91%和84%。对来自两个LV导联的分组窦性UPPA数据进行分析显示,敏感性分别为94%和91%。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验