用于在线耦合高效液相色谱的毛细管微萃取的超高稳定性、耐pH值的溶胶-凝胶二氧化钛聚(四氢呋喃)涂层。

Ultra-high-stability, pH-resistant sol-gel titania poly(tetrahydrofuran) coating for capillary microextraction on-line coupled to high-performance liquid chromatography.

作者信息

Segro Scott S, Cabezas Yaniel, Malik Abdul

机构信息

Department of Chemistry, University of South Florida, 4202 E. Fowler Avenue, CHE 205, Tampa, FL 33620-5250, USA.

出版信息

J Chromatogr A. 2009 May 15;1216(20):4329-38. doi: 10.1016/j.chroma.2009.03.036. Epub 2009 Mar 18.

Abstract

A sol-gel titania poly(tetrahydrofuran) (poly-THF) coating was developed for capillary microextraction hyphenated on-line with high-performance liquid chromatography (HPLC). Poly-THF was covalently bonded to the sol-gel titania network which, in turn, became chemically anchored to the inner surface of a 0.25mm I.D. fused silica capillary. For sample preconcentration, a 38-cm segment of the sol-gel titania poly-THF coated capillary was installed on an HPLC injection port as a sampling loop. Aqueous samples containing a variety of analytes were passed through the capillary and, during this process, the analytes were extracted by the sol-gel titania poly-THF coating on the inner surface of the capillary. Using isocratic and gradient elution with acetonitrile/water mobile phases, the extracted analytes were desorbed into the on-line coupled HPLC column for separation and UV detection. The sol-gel titania poly-THF coating was especially efficient in extracting polar analytes, such as underivatized phenols, alcohols, amines, and aromatic carboxylic acids. In addition, this coating was capable of extracting moderately polar and nonpolar analytes, such as ketones and polycyclic aromatic hydrocarbons. The sol-gel titania poly-THF coated capillary was also able to extract polypeptides at pH values near their respective isoelectric points. Extraction of these compounds can be important for environmental and biomedical applications. The observed extraction behavior can be attributed to the polar and nonpolar moieties in the poly-THF structure. This coating was found to be stable under extremely low and high pH conditions-even after 18h of exposure to 1M HCl (pH approximately 0.0) and 1M NaOH (pH approximately 14.0).

摘要

开发了一种溶胶 - 凝胶二氧化钛聚(四氢呋喃)(聚 - THF)涂层,用于与高效液相色谱(HPLC)在线联用的毛细管微萃取。聚 - THF共价键合到溶胶 - 凝胶二氧化钛网络上,而该网络又化学锚定在0.25mm内径的熔融石英毛细管的内表面。为了进行样品预浓缩,将一段38厘米长的溶胶 - 凝胶二氧化钛聚 - THF涂层毛细管作为采样环安装在HPLC进样口上。含有多种分析物的水性样品通过毛细管,在此过程中,分析物被毛细管内表面的溶胶 - 凝胶二氧化钛聚 - THF涂层萃取。使用乙腈/水流动相进行等度洗脱和梯度洗脱,萃取的分析物被解吸到在线联用的HPLC柱中进行分离和紫外检测。溶胶 - 凝胶二氧化钛聚 - THF涂层在萃取极性分析物方面特别有效,例如未衍生化的酚类、醇类、胺类和芳香族羧酸。此外,这种涂层能够萃取中等极性和非极性分析物,如酮类和多环芳烃。溶胶 - 凝胶二氧化钛聚 - THF涂层毛细管还能够在接近其各自等电点的pH值下萃取多肽。这些化合物的萃取对于环境和生物医学应用可能很重要。观察到的萃取行为可归因于聚 - THF结构中的极性和非极性部分。发现这种涂层在极低和极高的pH条件下都很稳定,即使在暴露于1M HCl(pH约为0.0)和1M NaOH(pH约为14.0)18小时后也是如此。

相似文献

3
Sol-gel immobilized short-chain poly(ethylene glycol) coating for capillary microextraction of underivatized polar analytes.
J Chromatogr A. 2007 Dec 7;1174(1-2):50-62. doi: 10.1016/j.chroma.2007.10.082. Epub 2007 Nov 1.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验