Halpern Ethan J, Takakuwa Kevin M, Gingold Eric L, Halpern David J
Department of Radiology, Thomas Jefferson University Hospital, 132 South 10th Street, Philadelphia, PA 19107-5244, USA.
Acad Radiol. 2009 Aug;16(8):951-6. doi: 10.1016/j.acra.2009.02.009. Epub 2009 Apr 17.
To determine whether angled gantry acquisition might be used to image the heart with a shorter scan length and reduced breast exposure during coronary computed tomography angiography.
One hundred consecutive coronary computed tomography angiography examinations of female patients were retrospectively evaluated to define the angle between the long axis of the left heart and the axial imaging plane. The scan length required to image the entire left ventricle along with the coronary arteries was measured for an axial scan plane as well as for a scan plane parallel to the long axis of the left heart. The overlap between these imaging volumes and the lower portion of the breast was measured.
The long axis of the left heart varied from 7 degrees to 54 degrees off the axial plane (mean 32 degrees +/- 7 degrees ). The required scan length to include the entire left ventricle and coronary arteries ranged from 8.2 to 12.4 cm (mean, 10.0 +/- 0.9 cm) for the axial scan plane and 5.6-10.1 cm (mean, 7.5 +/- 0.8 cm) for a scan plane parallel to the long axis of the heart (P < .001). cCTA in the axial plane required a 7.4 +/- 1.6 cm overlap with the lower breast, whereas cCTA in the long axis of the heart reduced the overlap to 4.5 +/- 1.8 cm (P < .001).
Using an angled gantry approach, the coronary arteries can be fully imaged in a plane along the long axis of the left heart with a single 10-cm acquisition and with substantial reduction in amount of breast tissue within the irradiated field.
确定在冠状动脉计算机断层扫描血管造影术中,倾斜机架采集是否可用于以更短的扫描长度和减少乳房受照剂量来对心脏进行成像。
回顾性评估连续100例女性患者的冠状动脉计算机断层扫描血管造影检查,以确定左心长轴与轴向成像平面之间的角度。测量沿轴向扫描平面以及与左心长轴平行的扫描平面成像整个左心室及冠状动脉所需的扫描长度。测量这些成像容积与乳房下部之间的重叠情况。
左心长轴与轴向平面的夹角为7度至54度(平均32度±7度)。轴向扫描平面成像整个左心室及冠状动脉所需的扫描长度为8.2至12.4厘米(平均10.0±0.9厘米),与心脏长轴平行的扫描平面为5.6 - 10.1厘米(平均7.5±0.8厘米)(P <.001)。轴向平面的冠状动脉计算机断层扫描血管造影与乳房下部的重叠为7.4±1.6厘米,而心脏长轴方向的冠状动脉计算机断层扫描血管造影将重叠减少至4.5±1.8厘米(P <.001)。
采用倾斜机架方法,可在沿左心长轴的平面内通过单次10厘米采集对冠状动脉进行完整成像,并大幅减少照射野内的乳房组织量。