Accurate measurement of sweat chloride concentration is essential for the diagnosis of cystic fibrosis (CF). We surveyed all laboratories enrolled in the Royal College of Pathologists of Australasia Quality Assurance Program (QAP) for Sweat Electrolytes to determine how closely they comply with the Australian Guidelines for the performance of the sweat test for the diagnosis of CF.
A detailed questionnaire covering most aspects of sweat collection and analysis was sent to all participating laboratories in 2007.
Twenty out of 38 laboratories completed the questionnaire. While adherence to accepted guidelines was noted in many areas, the following main variations were recorded: some laboratories were not doing enough sweat tests to maintain expertise; some were not collecting sweat for the recommended collection time; sweat conductivity was the only test available in some laboratories; there was a lack of agreement between the sweat chloride concentration used to indicate CF or define an equivocal result.
There is room for improvement in the performance of the sweat test in some laboratories in Australasia. The Sweat Testing Working Party of the Australasian Association of Clinical Biochemists is the appropriate body to address the problems involved in sweat testing and to bring about change.
准确测量汗液氯化物浓度对于囊性纤维化(CF)的诊断至关重要。我们对参与澳大拉西亚皇家病理学家学会汗液电解质质量保证计划(QAP)的所有实验室进行了调查,以确定它们在多大程度上符合澳大利亚CF诊断汗液试验操作指南。
2007年向所有参与实验室发送了一份涵盖汗液采集和分析大多数方面的详细问卷。
38个实验室中有20个完成了问卷。虽然在许多方面都注意到遵守了公认的指南,但记录到以下主要差异:一些实验室进行的汗液试验不足,无法保持专业水平;一些实验室没有按照推荐的采集时间采集汗液;一些实验室仅进行汗液电导率检测;在用于指示CF或定义不确定结果的汗液氯化物浓度方面缺乏一致性。